IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 21 - 40 of 98 [Previous]  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
MI 2021-03-17
13:30
Online Online Noise reduction method for sparse-view computed tomography using spatial frequency components
Takayuki Okamoto, Hideaki Haneishi (Chiba Univ.) MI2020-95
Sparse-view CT, an imaging technique to reduce the number of projections, can reduce the radiation dose and scanning dur... [more] MI2020-95
pp.207-211
CPSY, RECONF, VLD, IPSJ-ARC, IPSJ-SLDM [detail] 2021-01-25
16:45
Online Online Comparison of ICA Algorithms in the Compressed Sensing EEG Measurement Framework Using OD-ICA
Wataru Okumura, Daisuke Kanemoto, Osamu Maida, Tetsuya Hirose (Osaka Univ) VLD2020-52 CPSY2020-35 RECONF2020-71
Compressed sensing gives reduction of power consumption for electroencephalogram (EEG) measurement system. However, ocul... [more] VLD2020-52 CPSY2020-35 RECONF2020-71
pp.75-79
MI 2020-09-03
14:25
Online Online Proposal of 3D Generative Adversarial Network for Improving Image Ouality of Cone-Beam CT Images
Takumi Hase, Megumi Nakao (Kyoto Univ.), Keoho Imanishi (e-Growth Co., Ltd), Mitsuhiro Nakamura, Tetsuya Matsuda (Kyoto Univ.) MI2020-29
Artifacts and defects included in Cone-beam CT (CBCT) images have become an obstacle in radiation therapy and surgery su... [more] MI2020-29
pp.51-56
AP 2020-02-21
15:20
Shizuoka Shizuoka Univ. Hamamatsu Campus Study on Artifact Removal for Microwave Imaging
Tomoya Osaki, Mai Shiraki, Yoshihiko Kuwahara (Shizuoka Univ.) AP2019-196
In microwave imaging, false image generated from sources other than the target is called artifact. When microwaves imagi... [more] AP2019-196
pp.85-90
MI 2020-01-30
11:00
Okinawa OKINAWAKEN SEINENKAIKAN High precision metal artifacts reduction in X-ray CT images by Deep Image Prior and sinogram normalization
Hiroya Satake, Tatsuya Yokota (NIT), Yoshito Otake, Yoshinobu Sato (NAIST), Hidekata Hontani (NIT) MI2019-103
In this paper, we propose a method to improve the normalization accuracy of sinogram by using DeepImage Prior to remove ... [more] MI2019-103
pp.169-174
MI, MICT [detail] 2019-11-05
16:10
Ibaraki Univ. of Tsukuba [Short Paper] Proposal of fault-tolerant CT image reconstruction using Nonlocal Total Variation and its application to metal artifact reduction
Kazuki Chigita (Univ. Tsukuba), Jian Dong (TUTE), Yongchae Kim, Hiroyuki Kudo (Univ. Tsukuba) MICT2019-37 MI2019-64
When some abnormal data is included in the projection data, the normal image reconstruction method increases the influen... [more] MICT2019-37 MI2019-64
pp.55-56
SDM 2019-10-24
13:00
Miyagi Niche, Tohoku Univ. [Invited Talk] Random nanostructure formation and electric readout for nano-artifact metrics
Seiya Kasai, Renpeng Lu, Katsumi Shimizu, Xiang Yin (Hokkaido Univ.), Yosuke Ueba, Mikio Ishikawa, Mitsuru Kitamura (DNP), Morihisa Hoga (AIST), Makoto Naruse (Univ. of Tokyo), Tsutomu Matsumoto (YNU) SDM2019-62
We introduce a basic concept of nano-artifact metrics, expected to be a highly secure authentication technique using nan... [more] SDM2019-62
pp.45-50
RCC, MICT 2019-05-29
15:30
Tokyo TOKYO BIG SIGHT [Poster Presentation] A Real-Time Vital Information Monitoring for a Group of Exercisers -- Hardware Configuration of Wireless Vital Sensor Node --
Takunori Shimazaki (Osaka City Univ.), Takuma Hamagami, Yasukata Kawamoto (OKI), Hiroyuki Yomo (Kansai Univ.), Ryusuke Miyamoto (Meiji Univ.), Shinsuke Hara (Oosaka City Univ.) RCC2019-6 MICT2019-6
(To be available after the conference date) [more] RCC2019-6 MICT2019-6
pp.25-27
SDM, ED, CPM 2019-05-17
11:10
Shizuoka Shizuoka Univ. (Hamamatsu) Experimental Study on Optimization of 2D Random Nanostructure Formation and Electrical Readout for Nano Artifact Metrics
Renpeng Lu, Katsumi Shimizu, Xiang Yin (Hokkaido Univ.), Yosuke Ueba, Mikio Ishikawa, Mitsuru Kitamura (DNP), Seiya Kasai (Hokkaido Univ.) ED2019-24 CPM2019-15 SDM2019-22
For nano-artifact metrics utilizing resist collapse in nanometer-scale electron beam lithography, we investigate lithogr... [more] ED2019-24 CPM2019-15 SDM2019-22
pp.67-70
EMCJ, MICT
(Joint)
2019-03-15
11:30
Tokyo Kikai-Shinko-Kaikan Bldg. Effect of the position and pressure on the accuracy of PPG-based heart rate sensor
Yuzu Kuwahara, Masaya Kimoto, Takunori Shimazaki, Shinsuke Hara (Osaka City Univ.), Hiroyuki Yomo (Kansai Univ.) MICT2018-69
These days, because of its simplicity, noninvasiveness and unobtrusiveness, photoplethysmography (PPG) has been commonly... [more] MICT2018-69
pp.5-10
SRW 2018-08-20
14:00
Okayama Okayama Univ. Motion artifact removal in electrocardiogram estimation using wearable biosensors
Shohei Kozuki, Tadao Nakagawa (Tottori Univ.) SRW2018-17
Long-term electrocardiogram monitoring with wearable biosensors is attracting attention in healthcare application. Weara... [more] SRW2018-17
pp.47-50
RCC, MICT 2018-05-24
13:00
Tokyo Tokyo Big Sight [Poster Presentation] Effect of Fastening Belt Pressure on the Accuracy of Photoplethysmography-Based Heart Rate Sensing
Yuzu Kuwahara, Masaya Kimoto, Takunori Shimazaki (Osaka City Univ.), Hiroyuki Yomo (Kansai Univ.), Shinsuke Hara (Osaka City Univ.) RCC2018-1 MICT2018-1
Photoplethysmography (PPG) is non-invasive and unobtrusive, so it has been commonly used for heart rate (HR) sensing dur... [more] RCC2018-1 MICT2018-1
pp.1-6
HWS 2018-04-13
11:35
Fukuoka   Optical 3D Nano Artifact-metrics using White Light Interferometry
Naoki Yoshida (YNU), Yosuke Ueba, Shumpei Nishio, Yasuyuki Ohyagi (DNP), Morihisa Hoga (Compass21), Naoya Tate (KU), Makoto Naruse (NICT), Tsutomu Matsumoto (YNU) HWS2018-3
We propose an artificial-metric system which authenticates nanostructures with random irregularities by means of an inte... [more] HWS2018-3
pp.11-16
SIP, EA, SP, MI
(Joint) [detail]
2018-03-19
13:00
Okinawa   [Poster Presentation] Speaker verification based on non-linear bandwidth extension considering aliasing artifacts for super-wideband applications
Haruna Miyamoto, Sayaka Shiota, Hitoshi Kiya (Tokyo Metropolitan Univ.) EA2017-110 SIP2017-119 SP2017-93
This paper has two aims that are to propose a novel bandwidth extension (BWE) method considering aliasing artifacts, and... [more] EA2017-110 SIP2017-119 SP2017-93
pp.51-55
PRMU, BioX 2018-03-18
14:20
Tokyo   A Study of Fast Image Matching Method Under Translation, Scale and Rotation
Toru Takahashi, Kengo Makino, Yuta Kudo, Rui Ishiyama (NEC) BioX2017-42 PRMU2017-178
This paper presents a fast pattern matching method which covers image translation, rotation and scaling. Pattern matchin... [more] BioX2017-42 PRMU2017-178
pp.37-42
MBE, NC
(Joint)
2018-03-13
14:00
Tokyo Kikai-Shinko-Kaikan Bldg. Real-Time Artifact Reduction Using Sliding-Window Analysis for Real Data: A Functional Near-Infrared Spectroscopy Study
Yuta Oda, Takanori Sato, Isao Nambu, Yasuhiro Wada (NUT) MBE2017-85
Functional near-infrared spectroscopy (fNIRS) is an effective neuroimaging technique, which facilitates its real-time ap... [more] MBE2017-85
pp.29-34
ET 2018-03-03
12:30
Kochi Kochi University of Technology (Eikokuji Campus) Organization and Discovery Support System of Preferable Characteristics of Artifacts for Improving Kansei of Photographs
Masanobu Uesaka, Tomoko Kojiri (Kansai Univ.) ET2017-122
To create good artifacts, it is necessary to improve Kansei. Our research group had defined Kansei as common characteris... [more] ET2017-122
pp.193-198
SIS 2017-12-15
10:00
Tottori Tottori Prefectural Center for Lifelong Learning Elimination of high radioactivity data using forward-projection technique in myocardial perfusion SPECT image
Jo Mitsuzuka, Kazuhiro Sawa, Satoru Kishida (Tottori Univ.) SIS2017-48
Our purpose is to eliminate a high radioactivity data such as a gall bladder, in the projection data to reduce artifacts... [more] SIS2017-48
pp.85-87
EA, US
(Joint)
2017-01-26
11:20
Kyoto Doshisha Univ. Airborne ultrasonic position and velocity measurement by using two types of LPM signals and multiple moving objects tracking
Haruki Chiba, Ko Sakai, Shinnosuke Hirata (Tokyo Tech), Yuichiro Orino (The University of Shiga Prefecture), Minoru K Kurosawa (Tokyo Tech) US2016-112 EA2016-80
Ultrasonic distance measurement with pulse-echo is based on determination of the time of flight of ultrasonic pulses. In... [more] US2016-112 EA2016-80
pp.197-202(US), pp.73-78(EA)
EMM, ISEC, SITE, ICSS, IPSJ-CSEC, IPSJ-SPT [detail] 2016-07-15
15:20
Yamaguchi   A Durability Evaluation for Metallic-Foil Artifact-Metrics
Naoki Yoshida, Tsutomu Matsumoto (YNU) ISEC2016-37 SITE2016-31 ICSS2016-37 EMM2016-45
We proposed that metallic foils such as aluminum foils and gold foils can be applied to artifact-metrics, because the me... [more] ISEC2016-37 SITE2016-31 ICSS2016-37 EMM2016-45
pp.229-236
 Results 21 - 40 of 98 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan