Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
ICSS, IPSJ-SPT |
2023-03-13 13:10 |
Okinawa |
Okinawaken Seinenkaikan (Primary: On-site, Secondary: Online) |
sEMG-based Gesture Authentication for Smartwatch Akihisa Watanabe, Ryo Iijima, Tatsuya Mori (Waseda Univ.,) ICSS2022-50 |
We propose a gesture-based user recognition system using sEMG signals for smartwatches.
We designed the system to reali... [more] |
ICSS2022-50 pp.13-18 |
NC, MBE (Joint) |
2023-03-14 14:20 |
Tokyo |
The Univ. of Electro-Communications (Primary: On-site, Secondary: Online) |
Verification of Grasping Movement Distinction Accuracy of Myoelectric Prosthetic Hand System using Image Recognition Yuto Araki, Motoi Matsuda, Naohiro Fukumura (Toyohashi Univ. of Tech.) NC2022-104 |
Pattern recognition techniques using EMG have been actively studied. To use for prosthetics hand, EMG signal during the ... [more] |
NC2022-104 pp.72-77 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2022-11-30 15:50 |
Kumamoto |
(Primary: On-site, Secondary: Online) |
Design and Trial Production of Stochastic Resonance Processor using Differential Input Buffer in FPGA Akihiko Tsukahara, Sung-Gwi Cho, Keita Tanaka, Akihiko Homma, Yoshinori Uchikawa (Tokyo Denki Univ.) VLD2022-49 ICD2022-66 DC2022-65 RECONF2022-72 |
Stochastic resonance phenomenon is one of the methods that can detect weak signals buried in noise. In this paper, we pr... [more] |
VLD2022-49 ICD2022-66 DC2022-65 RECONF2022-72 pp.174-177 |
WIT, IPSJ-AAC |
2022-03-09 14:15 |
Online |
Online |
Development of Handrim Grasping Motion Assistance System for Wheelchair Users Takumi Ueno, Hirokazu Seki (CIT) WIT2021-56 |
In this study, we developed a wheelchair Handrim grasping assist system for people with spasticity in the fingers. We de... [more] |
WIT2021-56 pp.77-81 |
MICT, EMCJ (Joint) |
2022-03-04 10:05 |
Online |
Online |
A study on silent word recognition using various sensors Masaya Kusamoto, Kenko Ota (NIT) MICT2021-104 |
The aim of this study is to clarify the effectiveness of silent word recognition using multiple sensors. When a visible ... [more] |
MICT2021-104 pp.19-24 |
MBE, NC (Joint) |
2022-03-02 11:00 |
Online |
Online |
How attention affects neck muscle activations in head rotations Katsuya Takahashi, Kei Shimonishi, Kazuaki Kondo (Kyoto Univ.), Ito Takahide (RIKEN/Kyoto Univ.), Masashi Toda (Kumamoto Univ.), Junichi Akita (Kanazawa Univ.), Nakamura Yuichi (Kyoto Univ.) MBE2021-90 |
We employed EMG (electromyography) for investigating neck muscle activations in head rotations with different attentiona... [more] |
MBE2021-90 pp.13-16 |
MBE, NC (Joint) |
2022-03-02 11:25 |
Online |
Online |
An analytical study of habituation to rocking during standing position Yutaro Fujimoto (NIT, Tokuyama College), Yoshimitsu Hashizume (KIIS), Tomoko Hioki (YJC), Jun Nishii (Yamaguchi Univ.), Shoko Kaichida (NIT, Tokuyama College) MBE2021-91 |
In this study, the floor on which the subject stood was suddenly moved horizontally to the left and right. We analyzed t... [more] |
MBE2021-91 pp.17-20 |
BioX |
2020-11-25 13:25 |
Online |
Online |
A study of facial nerve palsy evaluation using surface electromyogram Kotaro Yamaguchi, Toshiko Yuji, Akira Ganaha, Tetsuya Tono, Hiroki Tamura (Univ. of Miyazaki) BioX2020-38 |
The diagnosis of facial nerve palsy consists of some diagnoses. The Yanagihara 40-point method and the ENoG value are us... [more] |
BioX2020-38 pp.15-19 |
HCGSYMPO (2nd) |
2019-12-11 - 2019-12-13 |
Hiroshima |
Hiroshima-ken Joho Plaza (Hiroshima) |
Analysis of kinesthetic sensation perceived by reaction force modulated by muscle activities Takumi Okada, Takahide Ito, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) |
(To be available after the conference date) [more] |
|
PRMU, MVE, IPSJ-CVIM [detail] |
2019-01-18 10:00 |
Kyoto |
|
Variable Motion Indication for On-Neck Communication
-- variation and selection with wrist-watch type device -- Takahide Ito, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Jonathan Rossiter (Bristol Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) PRMU2018-106 MVE2018-48 |
今後の英語論文投稿時に二重投稿と判断されないよう、今回は英文のアブストラクトを省略したい。 [more] |
PRMU2018-106 MVE2018-48 pp.115-120 |
HCGSYMPO (2nd) |
|
Mie |
Sinfonia Technology Hibiki Hall Ise |
Temporal analysis and visualization of muscle synergy induced by a haptic device Takumi Okada, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) |
(To be available after the conference date) [more] |
|
WIT, SP |
2018-10-27 13:50 |
Fukuoka |
Kyushu Institute of Technology(Kitakyushu) |
Proposal of Esophageal Speech Training Device with Myoelectric Signal
-- Identification of Myoelectric Signal Detection Spot for Training Device -- Katsutoshi Oe (DIT), Ryoya Nakamura (Kyutech), Kazutaka Hosokawa (DIT) SP2018-34 WIT2018-22 |
The patients who undergo the laryngectomy lose their voice. One of the speech production substitutes that are used by vo... [more] |
SP2018-34 WIT2018-22 pp.13-16 |
HIP |
2018-10-22 14:30 |
Kyoto |
Kyoto Terrsa |
Prediction of standing up motion
-- motion prediction using EMG and posture measurement -- Kenji Takeda, Takahide Ito, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) HIP2018-58 |
(To be available after the conference date) [more] |
HIP2018-58 pp.9-12 |
WIT |
2018-06-09 15:30 |
Kanagawa |
|
Identification of Tongue Motion and Silent Vowel based on EMG Tadahiro Oyama (KCCT), Taisei Watanabe (NAIST) WIT2018-4 |
In this paper, we propose a method to estimate the tongue motion direction and silent speech based on convolutional neur... [more] |
WIT2018-4 pp.17-20 |
PRMU, MI, IE, SIP |
2018-05-17 16:15 |
Gifu |
|
Motion Monitoring using Skin-Stretcher Device Takahide Ito, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Jonathan Rossiter (Bristol Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) SIP2018-5 IE2018-5 PRMU2018-5 MI2018-5 |
This paper introduces a novel design of a motion monitoring system through neck muscle measurement and skin-stretch stim... [more] |
SIP2018-5 IE2018-5 PRMU2018-5 MI2018-5 pp.17-22 |
EMM |
2018-03-05 15:45 |
Kagoshima |
Naze Community Center (Amami-Shi, Kagoshima) |
[Poster Presentation]
A Study on Face Anti-spoofing Kazuyoshi Nomoto, Hyunho Kang (NIT, Tokyo College) EMM2017-87 |
(To be available after the conference date) [more] |
EMM2017-87 pp.51-53 |
ED, SDM |
2017-02-24 15:15 |
Hokkaido |
Centennial Hall, Hokkaido Univ. |
Application of Carbon Nanotube Composite Paper to Surface Electrodes for Myoelectric Signal Detection Yuki Inden, Seiya Kasai, Kento Shirata, Kazuki Inada (Hokkaido Univ.) ED2016-138 SDM2016-155 |
We investigate the application of carbon nanotube (CNT) composite paper to surface electrodes for surface myoelectric si... [more] |
ED2016-138 SDM2016-155 pp.47-51 |
MBE, NC (Joint) |
2016-12-07 13:55 |
Aichi |
Toyohashi University of Technology |
A Study of the System to Control Static Upright Posture of Humans Jono Yusuke, Takada Hiroki (Fukui Univ) MBE2016-62 |
Humans spend most of their everyday life in standing position. If it were difficult to maintain an upright posture, we w... [more] |
MBE2016-62 pp.31-34 |
MI, MICT |
2016-09-16 16:20 |
Tokyo |
Koganei Campus, Tokyo University of Agriculture and Technology |
Preliminary study for measuring the state of upper arm muscle by ultrasonic echo and electromyogram Marie Tabaru, Takahiro Aoyagi (Tokyo Tech) MICT2016-46 MI2016-60 |
Body area network (BAN) requires increasing kinds of bio-information to be treated and development
of sensors to detect... [more] |
MICT2016-46 MI2016-60 pp.57-61 |
AI |
2016-06-27 10:40 |
Tokyo |
|
Locomotive Control of Omnidirectional Wheelchair Robot Using Electromyograph Sensor Yoichiro Maeda (IOT), Shoji Ishibashi (UH) AI2016-2 |
In recent years, the research and development of nursing and welfare robots, devices and systems intended for people wit... [more] |
AI2016-2 pp.7-12 |