Tohoku Univ. and Online (Primary: On-site, Secondary: Online) |
Evaluation of trabecula using photoacoustic technique Taishi Hattori, Takeru Kuroiwa, Tatsuya Ugumori, Mami Matsukawa (Doshisha Univ.) US2023-39 |
We focused on the photoacoustic technique in order to understand the changes in physical properties of trabecula, which ... [more] |
US2023-39 pp.11-14 |
MBE |
2019-05-19 09:50 |
Niigata |
Niigata University |
Quantitative evaluation of the femoral condylar shape in the knee joint with the discoid meniscus Takeru Hirano, Toyohiko Hayashi (Niigata Univ), Satoshi Watanabe (Niigata Medical Center) MBE2019-3 |
In order to reduce the load working on the knee joint, two meniscuses are placed as soft tissue on the lateral and media... [more] |
MBE2019-3 pp.13-18 |
MBE |
2014-06-13 15:20 |
Hokkaido |
Hokkaido Univerisity |
MR imaging-based thickness analysis of the growth plate in the femoral distal end Shota Tanaka, Toyohiko Hayashi (Niigata Univ.), Satoshi Watanabe (Niigata Medical Center), Yoshio Koga (Ninouji Hot Spring Hospital), Go Omori (Niigata Univ. of Health and Welfare) MBE2014-24 |
The growth plate is a planar cartilage located in the epiphysis, having a function of growing bone. Then its damage resu... [more] |
MBE2014-24 pp.57-62 |
MI |
2011-01-20 11:30 |
Okinawa |
Naha-Bunka-Tembusu |
Assessment of effect of braces on 3D motion of knee joint Takashi Ohnishi, Masahiko Suzuki, Tatsuya Kobayashi (Chiba Univ.), Shinji Naomoto, Atsushi Nawata (Alcare), Hideaki Haneishi (Chiba Univ.) MI2010-93 |
Three-dimensional(3D) motion information of bones of knee joint during knee bends is helpful for evaluation and developm... [more] |
MI2010-93 pp.69-72 |
MI |
2010-01-28 11:40 |
Okinawa |
Naha-Bunka-Tenbusu |
Extraction of clinically used parameters from three-dimensional motion data of a knee joint Takashi Ohnishi, Masahiko Suzuki, Tatsuya Kobayashi (Chiba Univ.), Shinji Naomoto, Atsushi Nawata (Alcare Co,. Ltd.), Hideaki Haneishi (Chiba Univ.) MI2009-108 |
We have proposed a method for 3D motion acquisition using bi-plane fluoroscopy and CT images. It only provides rotation ... [more] |
MI2009-108 pp.179-182 |
MBE |
2007-05-25 14:10 |
Toyama |
Toyama Univ. |
Development of highly-reproducible anatomical coordinate system of fumer for MR model. Shuichi Ishiya, Toyohiko Hayashi, Yasuo Nakamura (Niigata Univ.), Satoshi Watanabe (Niigata Kobari Hospital), Go Omori (Niigata Univ.) MBE2007-10 |
In order to evaluate patient’s knee motion, 3-D bone model-based approaches are employed by combining a fluoroscopic ima... [more] |
MBE2007-10 pp.37-40 |
PRMU, MI |
2007-05-24 11:40 |
Mie |
Mie Univ. |
Semi-automated Segmentation of the Femur from 3D CT Images Using Multi-Level Statistical Shape Model Futoshi Yokota (Kobe Univ.), Ryuji Shimada, Toshiyuki Okada (Osaka Univ.), Yoshiyuki Kagiyama (Kobe Univ.), Masahiko Nakamoto (Osaka Univ.), Masaki Takao (Osaka Koseinenkin Hospital), Nobuhiko Sugano, Yoshinobu Sato, Hideki Yoshikawa (Osaka Univ.), Yukio Tada (Kobe Univ.) PRMU2007-9 MI2007-9 |
We have been developed automated preoperative planning system for total hip arthrorplasty. One problem in preprocessing ... [more] |
PRMU2007-9 MI2007-9 pp.47-52 |
|
|
|
Copyright and reproduction :
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)
|