Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI, IE, SIP, BioX, ITE-IST, ITE-ME [detail] |
2020-05-28 12:40 |
Online |
Online |
[Special Talk]
Generalization of coherent point drift and its acceleration Osamu Hirose (Kanazawa Univ.) SIP2020-1 BioX2020-1 IE2020-1 MI2020-1 |
Point set registration is to find point-to-point correspondences between point sets, each of which represents the shape ... [more] |
SIP2020-1 BioX2020-1 IE2020-1 MI2020-1 pp.1-3 |
MI |
2020-01-30 15:00 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
[Short Paper]
3D Brain Atlas Construction from Single Japanese Cadaver Brain Yota Noda, Ken'ichi Morooka (Kyushu Univ.), Yasushi Miyagi (Fukuoka Mirai Hospital), Takaichi Fukuda (Kumamoto Univ.), Shoko Miyauchi, Ryo Kurazume (Kyushu Univ.) MI2019-119 |
We have been constructing the 3D brain atlas from a single Japanese cadaver brain. In constructing the atlas, a 3D digit... [more] |
MI2019-119 pp.231-234 |
MI |
2020-01-30 15:40 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
Study on non-rigid registration of clinical chest CT volumes and micro CT volumes of excised lung specimen Shinya Hatakoshi, Hirohisa Oda, Yuichiro Hayashi, Holger R. Roth, Shouta Nakamura, Masahiro Oda (Nagoya Univ.), Masaki Mori (Sapporo-Kosei General Hosp.), Hirotsugu Takabatake (Sapporo Minami-sanjo Hosp.), Hiroshi Natori (Keiwakai Nishioka Hosp.), Kensaku Mori (Nagoya Univ.) MI2019-123 |
(To be available after the conference date) [more] |
MI2019-123 pp.249-254 |
SIP, MI, IE |
2019-05-24 14:00 |
Aichi |
|
Analysis of deaeration deformation for ex vivo animal lung Kotaro Kobayashi, Megumi Nakao, Junko Tokuno, Toyofumi F. Chen-Yoshikawa, Hiroshi Date, Tetsuya Matsuda (Kyoto Univ.) SIP2019-12 IE2019-12 MI2019-12 |
Recent advance of imaging techniques enables to visualize minute lung nodules in the early stage cancer. Although lung n... [more] |
SIP2019-12 IE2019-12 MI2019-12 pp.53-58 |
IMQ, IE, MVE, CQ (Joint) [detail] |
2019-03-14 17:10 |
Kagoshima |
Kagoshima University |
[Invited Talk]
Pattern Optimization Using Evolutionary Computation Satoshi Ono (Kagoshima Univ.) IMQ2018-51 IE2018-135 MVE2018-82 |
This study focuses Evolutionary Computation (EC) that is a black-box optimization framework for non-differentiable, glob... [more] |
IMQ2018-51 IE2018-135 MVE2018-82 pp.165-171 |
PRMU, IBISML, IPSJ-CVIM [detail] |
2018-09-21 13:50 |
Fukuoka |
|
Multi-modal image registration based on local mutual information Hiroaki Tani, Toshikazu Wada (Wakayama Univ) PRMU2018-65 IBISML2018-42 |
In recent years, various types of images having different modality from visible-light images, such as infrared images, d... [more] |
PRMU2018-65 IBISML2018-42 pp.207-212 |
PRMU, MI, IE, SIP |
2018-05-18 16:00 |
Gifu |
|
[Short Paper]
Ryoma Bise (Kyushu Univ.), Zheng Yinqiang, Imari Sato (NII) SIP2018-17 IE2018-17 PRMU2018-17 MI2018-17 |
Photoacoustic imaging (PAI) is a new imaging technology that can non-invasively visualize blood vessels inside biologica... [more] |
SIP2018-17 IE2018-17 PRMU2018-17 MI2018-17 pp.75-79 |
SIP, EA, SP, MI (Joint) [detail] |
2018-03-19 10:20 |
Okinawa |
|
Automatic extraction of ultrasonic measurement area from pathological image for registration with ultrasonic image Maho Funato, Takashi Ohnishi, Shu Kashio, Kazuyo Ito, Tadashi Yamaguchi, Yasuo Iwadate, Hideaki Haneishi (Chiba Univ.) MI2017-66 |
We have been developing the registration between the pathological image and ultrasonic image by a scanning acoustic micr... [more] |
MI2017-66 pp.13-16 |
MI, MICT |
2017-11-06 10:00 |
Kagawa |
Sunport Hall Takamatsu |
Automated Initialization of 2D-3D Registration of Rib Cage from Chest Radiography using Convolutional Neural Network Mototaka Kabashima, Yuta Hiasa, Yoshito Otake (NAIST), Rie Tanaka, Shigeru Sanada (Kanazawa Univ.), Yoshinobu Sato (NAIST) MICT2017-27 MI2017-49 |
The difficulties in automation of 2D-3D registration are two-folds: initialization and failure detection. In this paper,... [more] |
MICT2017-27 MI2017-49 pp.5-8 |
MI, MICT |
2017-11-06 15:10 |
Kagawa |
Sunport Hall Takamatsu |
Reconstruction of dynamic-3D ultrasound image with mechanical linear guide for muscle function analysis
-- Validation of slice-to-volume registration -- Tokumi Sano, Norio Fukuda, Yoshito Otake (NAIST), Shingo Abe, Shoji Konda (Osaka Univ.), Yoshinobu Sato (NAIST) MICT2017-37 MI2017-59 |
Analysis of three-dimensional structure of muscles and its movement is important for sports science and rehabilitation. ... [more] |
MICT2017-37 MI2017-59 pp.53-57 |
MI |
2017-07-06 16:15 |
Miyagi |
Tohoku Univ. |
An Automated Method for Generating Training Data for Image Registration Using Deep Learning Masato Ito, Fumihiko Ino, Kenichi Hagihara (Osaka Univ.) MI2017-28 |
In this paper, we propose an automated method for generating training data that realizes image registration with deep le... [more] |
MI2017-28 pp.11-16 |
MI |
2017-01-18 10:05 |
Okinawa |
Tenbusu Naha |
Non-rigid registration of human embryo serial-section images by blending of rigid transforms Takehiro Kajihara, Takuya Funatomi (NAIST), Haruyuki Makishima (Kyoto Univ.), Takahito Aoto, Hiroyuki Kubo (NAIST), Shigehito Yamada (Kyoto Univ.), Yasuhiro Mukaigawa (NAIST) MI2016-71 |
(To be available after the conference date) [more] |
MI2016-71 pp.1-6 |
MI |
2017-01-18 14:15 |
Okinawa |
Tenbusu Naha |
[Short Paper]
Syougo Yokoi, Yuta Takeda, Takeshi Hara (Gifu Univ.), Yuki Tanaka (St. Luke's International Hospital), Tetsuro Katafuchi (Gifu Medical Science Univ.), Daisuke Fukuoka (Gifu Univ.), Taiki Nozaki, Masaki Matsusako (St. Luke's International Hospital), Hiroshi Fujita (Gifu Univ.) MI2016-91 |
(To be available after the conference date) [more] |
MI2016-91 pp.77-78 |
HCGSYMPO (2nd) |
2016-12-07 - 2016-12-09 |
Kochi |
Kochi City Culture Plaza (CUL-PORT) |
Automatic Calibration for Large-scale Projector-Camera System Chun Xie, Yoshinari Kameda, Kenji Suzuki, Itaru Kitahara (Univ. of Tsukuba) |
We are introducing large-scale projection mapping system to school gymnasium aiming to support school activities. Large-... [more] |
|
US |
2016-05-23 14:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Basic examination for analyzing acoustic characteristics of cell organelle Deng ZhiHao, Kazuyo Ito, Kenji Yoshida, Hitoshi Maruyama, Tadashi Yamaguchi (Chiba Univ.) US2016-15 |
This paper demonstrate the measurement of speed of sound (SOS) in different disease model (cirrhotic model and normal mo... [more] |
US2016-15 pp.19-24 |
PRMU, IE, MI, SIP |
2016-05-20 15:40 |
Aichi |
|
Highly Accurate Reconstruction of Microscope 3D images based on Micro Anatomic Structures Hirokazu Kobayashi, Hidekata Hontani (NIT) SIP2016-29 IE2016-29 PRMU2016-29 MI2016-29 |
The objective of this research is to develop a method for accurately
registering 2D microscope images of spatially succ... [more] |
SIP2016-29 IE2016-29 PRMU2016-29 MI2016-29 pp.153-156 |
ITS, IE, ITE-AIT, ITE-HI, ITE-ME, ITE-MMS, ITE-CE [detail] |
2016-02-23 11:45 |
Hokkaido |
Hokkaido Univ. |
Satellite Image Registration Based on Minimization of Distance between Panchromatic Image and Synthesized Image from Multispectral Images Momoyo Nagase, Hideaki Maehara, Shunichi Sekiguchi (Mitsubishi Electric Corp.) ITS2015-80 IE2015-122 |
Satellites have both panchromatic sensors and multispectral sensors. Pansharpen is a multisensory fusion technique which... [more] |
ITS2015-80 IE2015-122 pp.265-268 |
MI |
2016-01-19 13:20 |
Okinawa |
Bunka Tenbusu Kan |
Source Localization in Remote After Loading System Using CT Image and Radiograph Yuki Miyajima, Takayuki Kanai, Koji Suzuki (yamagata univ.), Satoshi Saito (Toshiba medical systems), Tetsuya Yuasa, Kenji Nemoto (yamagata univ.) MI2015-87 |
RALS (Remote After Loading System) which is a kind of radiation therapy are widely applied to the treatment for cervical... [more] |
MI2015-87 pp.75-80 |
MI |
2016-01-20 13:05 |
Okinawa |
Bunka Tenbusu Kan |
Evaluation of Image Quality and Registration Accuracy of 3D Ultrasound Portal Vein Images for Long Monitoring Iori Terada, Toshiki Teratoko, Tomohiro Ueno, Koich Ishizu, Yasutomo Fujii, Tsuyoshi Shiina, Naozo Sugimoto (Kyoto Univ) MI2015-123 |
Continuous 3D Ultrasound monitoring may capture important physiological changes as well as Holter electrocardiography. A... [more] |
MI2015-123 pp.241-246 |
MI |
2016-01-20 14:02 |
Okinawa |
Bunka Tenbusu Kan |
Non-Rigid Registration of Brain Block Models for Constructing 3D Japanese Brain Atlas Shou Sasaki, Ken'ichi Morooka, Shoko Miyauchi, Tokuo Tsuji (Kyushu Univ.), Yasushi Miyagi (Kaizuka Hospital), Takaichi Fukuda (Kumamoto Univ.), Kazuhiro Samura (Fukuoka Univ.), Ryo Kurazume (Kyushu Univ.) MI2015-136 |
We have been constructing the 3D atlas of a Japanese braincite{japanese_atlas}. In constructing the atlas, we cut a cada... [more] |
MI2015-136 pp.309-313 |