Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
US, EA (Joint) |
2013-01-25 13:10 |
Kyoto |
Kambaikan, Doshisha Univ. |
[Invited Talk]
Recent Advances on Active Noise Control: Open Issues and Innovative Applications Yoshinobu Kajikawa (Kansai Univ.) US2012-106 EA2012-137 |
The problem of acoustic noise is becoming increasingly serious with the growing use of industrial and medical equipment,... [more] |
US2012-106 EA2012-137 pp.101-106(US), pp.103-108(EA) |
EA, SP, SIP |
2012-05-24 13:20 |
Osaka |
Osaka Univ. Nakanoshima Center |
Statistical mechanical of the FXLMS algorithm and its accuracy Seiji Miyoshi, Yoshinobu Kajikawa (Kansai Univ.) EA2012-10 SIP2012-10 SP2012-10 |
We analyze the dynamical behaviors (learning curves) of active noise control with FXLMS algorithm using statistical mech... [more] |
EA2012-10 SIP2012-10 SP2012-10 pp.53-58 |
EA, SP, SIP |
2012-05-24 13:45 |
Osaka |
Osaka Univ. Nakanoshima Center |
A Feedback ANC System Using Virtual Microphone Nobuhiro Miyazaki, Yoshinobu Kajikawa (Kansai Univ.) EA2012-11 SIP2012-11 SP2012-11 |
Feedback active noise control (ANC) system consists of an error microphone and a secondary source.Even if the noise is g... [more] |
EA2012-11 SIP2012-11 SP2012-11 pp.59-64 |
CAS, CS, SIP |
2012-03-09 10:10 |
Niigata |
The University of Niigata |
Active Noise Control System for Factory Noise Hirofumi Tetsu, Yoshinobu Kajikawa (Kansai Univ.) CAS2011-152 SIP2011-172 CS2011-144 |
Manufacturing equipment generates a serious noise (over 90 dB) in the factory. Hence, workers are exposed to the industr... [more] |
CAS2011-152 SIP2011-172 CS2011-144 pp.251-256 |
EA, US (Joint) |
2012-01-27 14:45 |
Osaka |
Kansai Univ. |
Modified Error Feedback ANC System Robust Against Disturbance Shinya Okuno, Yoshinobu Kajikawa (Kansai Univ.) EA2011-119 |
Feedback active noise control (ANC) system which is effective for
narrowband noise can get an input signal and monitor ... [more] |
EA2011-119 pp.95-100 |
EA |
2011-08-09 14:45 |
Miyagi |
RIEC, Tohoku Univ. |
Feedback Active Noise Control System for Reducing MR Noise
-- Stability Improvement of ANC System Using Linear Prediction Filter -- Hiroyasu Kobayashi, Yoshinobu Kajikawa (Kansai Univ.) EA2011-53 |
MRI (Magnetic Resonance Imaging) device is medical equipment which has been used to obtain the
cross-sectional image of... [more] |
EA2011-53 pp.19-24 |
EA |
2011-07-15 16:30 |
Osaka |
Campus Port Osaka |
Modified-Error Filtered-x algorithm employing linear prediction filter Shinya Okuno, Yoshinobu Kajikawa (Kansai Univ.) EA2011-48 |
Feedback active noise control (ANC) system which is effective for narrowband noise can get an input signal and monitor t... [more] |
EA2011-48 pp.33-38 |
MSS, CAS, VLD, SIP |
2011-06-30 10:00 |
Okinawa |
Okinawa-Ken-Seinen-Kaikan |
Statistical Mechanical Analysis of the Filtered-X LMS Algorithm (II) Seiji Miyoshi, Yoshinobu Kajikawa (Kansai Univ.) CAS2011-4 VLD2011-11 SIP2011-33 MSS2011-4 |
We analyze the dynamical behaviors (learning curves) of active noise control with Filtered-X LMS algorithm using statist... [more] |
CAS2011-4 VLD2011-11 SIP2011-33 MSS2011-4 pp.19-24 |
EA |
2011-06-23 14:00 |
Hokkaido |
Health Sci. Univ. of Hokkaido |
Improvement of Noise Reduction Performance of ANC Systems with Online Secondary Path Modeling Technique using Two Secondary Path Models Akihisa Oishi, Muhammad Tahir Akhtar, Wataru Mitsuhashi (UEC) EA2011-31 |
A new technique is proposed for a controlled injection of the noise to model the secondary acoustic path in the feedforw... [more] |
EA2011-31 pp.7-12 |
CAS, MSS, VLD, SIP |
2010-06-21 15:20 |
Hokkaido |
Kitami Institute of Technology |
Stability Improvement of IMC Based Active Noise Control system Employing Linear Prediction Filter Yoshinobu Kajikawa, Ryotaro Hirayama (Kansai Univ.) CAS2010-13 VLD2010-23 SIP2010-34 CST2010-13 |
In this paper, we propose a feedback active noise control (ANC) system combining a linear prediction filter. The propose... [more] |
CAS2010-13 VLD2010-23 SIP2010-34 CST2010-13 pp.69-74 |
SP, EA, SIP |
2010-05-27 10:55 |
Hyogo |
Konan Univ. (Hirao Seminar House) |
Active Noise Control for MR Noise Yoshinobu Kajikawa, Masahiro Kida, Ryotaro Hirayama (Kansai Univ.), Tohru Tani, Yoshimasa Kurumi (Shiga Univ. of Medical Sci.) EA2010-14 SIP2010-14 SP2010-14 |
This paper proposes an active noise control (ANC) system reducing periodic noises generated under the high-field area su... [more] |
EA2010-14 SIP2010-14 SP2010-14 pp.79-84 |
EA, US (Joint) |
2010-01-26 14:00 |
Osaka |
|
Robust Feedback Active Noise Control System under Wideband Disturbance Ryotaro Hirayama, Yoshinobu Kajikawa (Kansai Univ.) EA2009-113 |
Feedback active noise control (ANC) system which is effective for narrowband noise can get an input signal and monitor p... [more] |
EA2009-113 pp.83-88 |
EA, SIP, SP |
2009-05-28 16:00 |
Hyogo |
|
Active noise control in a duct by an analog neural network circuit Masashi Kato, Koji Onoda, Toshihiro Tanaka (Nagoya Inst. of Tech.) EA2009-6 SIP2009-6 SP2009-11 |
Although active noise control (ANC) in acoustic field of ducts has been applied with digital signal processing, the ANC ... [more] |
EA2009-6 SIP2009-6 SP2009-11 pp.29-33 |
EA, US (Joint) |
2009-01-30 10:35 |
Kyoto |
|
Head-mounted Active Noise Control System for Reducing MR Noise Masahiro Kida, Ryotaro Hirayama, Yoshinobu Kajikawa (Kansai Univ.), Tohru Tani, Yoshimasa Kurumi (Shiga Univ.) EA2008-126 |
MRI(Magnetic Resonance Imaging) device is medical equipment which has been used to obtain the cross-sectional image of t... [more] |
EA2008-126 pp.61-66 |
EA |
2008-10-24 14:45 |
Toyama |
|
Control System for Bone-conducted Speech by Earplug Type Transducer Yasuhiro Kawaguchi, Kenji Furihata (Shinshu Univ.) EA2008-82 |
Stuttering is caused by bone-conduced speech feedback. If bone-conducted speech can be controlled, stuttering can be cor... [more] |
EA2008-82 pp.103-108 |
SIP, EA |
2008-05-29 13:00 |
Osaka |
Kansai Univ. |
A Realization of Active Noise Control System for MR Noise.
-- A Study on the Feedback ANC System -- Masahiro Kida, Ryotaro Hirayama, Yusuke Ono, Daisuke Tokunaga, Yoshinobu Kajikawa (Kansai Univ.), Tohru Tani, Yoshimasa Kurumi (Shiga Univ.), Yasuo Nomura (Kansai Univ.) EA2008-9 SIP2008-18 |
MRI(Magnetic Resonance Imaging) machine is medical equipment system which has been used to obtain the cross-sectional im... [more] |
EA2008-9 SIP2008-18 pp.19-24 |
EA, US (Joint) |
2008-01-29 15:15 |
Osaka |
Kansai University |
A Realization of Active Noise Control System for MR Noise
-- A Study on the Available ANC System in Magnetic Field -- Yusuke Ono, Daisuke Tokunaga, Yoshinobu Kajikawa (Kansai Univ.), Tohru Tani, Yoshimasa Kurumi (Shiga Univ. of Medical Science), Yasuo Nomura (Kansai Univ.) EA2007-110 |
MRI(Magnetic Resonance Imaging) is a medical equipment system which in late years has been used to obtain the cross-sect... [more] |
EA2007-110 pp.53-58 |
EA |
2007-04-27 13:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg (Tokyo, Japan) |
Subjective Effect of ANC System and it's Evaluation Methods. Yuko Watanabe, Sayoko Utsumi, Eiji Murai, Hareo Hamada (TDU), Shinsuke Mitsuhata (Asahi Beer), Shin'ichi Abe (TOA) EA2007-1 |
This paper will deal with the subjective effects of active noise control(ANC) system. To design a highly effective ANC s... [more] |
EA2007-1 pp.1-6 |
EA, SIP |
2006-05-25 15:50 |
Hyogo |
EGRET Himeji |
Improvement of Convergence Speed for Active Noise Control Using the Simultaneous Perturbation Method Yukinobu Tokoro, Yoshinobu Kajikawa, Yasuo Nomura (Kansai Univ.) |
Active noise control (ANC) system using the simultaneous perturbation method has an excellent feature that the excited n... [more] |
EA2006-12 SIP2006-16 pp.23-28 |
EA |
2005-12-16 14:30 |
Tokyo |
|
Active Noise Control System Using Refined Filtering Approach Kouta Isozaki, Yusuke Tsuda, Tetsuya Shimamura (Saitama Univ.) |
(To be available after the conference date) [more] |
EA2005-87 pp.45-50 |