IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 21 - 40 of 51 [Previous]  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
US 2019-12-11
15:25
Tokyo   Relationship between particle size and effect of aerosol agglomeration by aerial ultrasonic source integrated cylindrical rigid wall
Rintaro Motoi, Takuya Asami, Hikaru Miura (Nihon Univ) US2019-68
Aerial ultrasonic waves are known to induce vibrations of the particles present in the air and cause aggregation due to ... [more] US2019-68
pp.19-24
EA, US
(Joint)
2019-01-22
10:30
Kyoto Doshisha Univ. [Poster Presentation] Observation of aerosolized aggregated particles by aerial intense ultrasonic waves
Rintaro Motoi, Takuya Asami, Hikaru Miura (Nihon Univ.) US2018-81
 [more] US2018-81
pp.13-16
EA, US
(Joint)
2019-01-22
10:30
Kyoto Doshisha Univ. [Poster Presentation] Fundamental investigation of cleaning effect in running water type ultrasonic cleaning using 27 kHz vibration source
Hidenobu Hosaka, Takuya Asami, Hikaru Miura (Nihon Univ.) US2018-82
 [more] US2018-82
pp.17-20
EA, US
(Joint)
2019-01-22
10:30
Kyoto Doshisha Univ. [Poster Presentation] Welding of Coated Twisted Wire and Copper Plate using 40kHz Ultrasonic Longitudinal Vibration
Shinya Oishi, Takuya Asami, Hikaru Miura (Nihon Univ.) US2018-83
 [more] US2018-83
pp.21-24
US 2018-12-10
16:15
Tokyo   Ultrasonic welding of dissimilar metals using planar vibration -- In the case of changing size and installation direction of the welding sample --
Yosuke Tamada, Takuya Asami, Hikaru Miura (Nihon Univ.) US2018-76
Since ultrasonic welding does not use heat, welding of dissimilar metals having different melting points can be easily p... [more] US2018-76
pp.33-38
US 2018-05-21
13:55
Tokyo   Development of Cylinder Typed Vibrating Plate with Rigid Wall Using FEM
Takuya Asami, Hikaru Miura (Nihon Univ.) US2018-12
Application of high power aerial ultrasonic waves include agglomeration of aerosol and fine particles and reduction of p... [more] US2018-12
pp.7-12
US 2017-12-11
13:30
Tokyo   Welding of Coated Copper Wire and Aluminum Plate by Using Ultrasonic Vibration -- Peeling Condition of the Coating --
Hisato Suzuki, Shinya Oishi, Takuya Asami, Hikaru Miura (Nihon Univ.) US2017-74
In recent years, there has been a demand for joining coated copper wires and solder electrodes in various electronic com... [more] US2017-74
pp.1-6
US 2017-12-11
13:55
Tokyo   Investigation of dissimilar metal welding using planar locus by ultrasonic complex vibration source
Yosuke Tamada, Hidenobu Hosaka, Takuya Asami, Hikaru Miura (Nihon Univ) US2017-75
An ultrasonic welding method is one of the welding methods of dissimilar metals. Many of the conventional methods are ul... [more] US2017-75
pp.7-10
US 2017-05-22
15:25
Tokyo   Ultrasonic welding by complex vibration source consisting of longitudinal and torsional vibration transducers -- Study of varying shape of vibration locus --
Takuya Asami, Yosuke Tamada, Yusuke Higuchi, Hikaru Miura (Nihon Univ.) US2017-18
We developed an ultrasonic complex vibration source using longitudinal vibration transducer and torsional vibration tran... [more] US2017-18
pp.23-26
EA, US
(Joint)
2017-01-25
13:00
Kyoto Doshisha Univ. [Poster Presentation] Welding of coated copper wire and aluminum plate by ultrasonic vibration -- Relationship between welding time and weld strength --
Hisato Suzuki, Takuya Asami, Hikaru Miura (Nihon Univ.) US2016-94
In recent years, there has been a demand for joining coated copper wires and solder electrodes in various electronic com... [more] US2016-94
pp.117-121
US 2016-12-12
13:30
Tokyo   Study of ultrasonic welding by complex vibration source consisting of longitudinal and torsional vibration transducers
Takuya Asami, Yusuke Higuchi, Hikaru Mirua (Nihon Univ.) US2016-64
 [more] US2016-64
pp.19-22
US 2016-12-12
13:55
Tokyo   Welding of Copper Plate and Aluminum Plate by Ultrasonic Complex Vibration -- Study by Several Vibration Loci --
Yusuke Higuchi, Takuya Asami, Hikaru Miura (Nihon Univ.) US2016-65
The electric vehicle is needs for the large capacity of batteries, and the dissimilar metal of an aluminum plate and a c... [more] US2016-65
pp.23-28
US 2016-12-12
14:45
Tokyo   Development of aerial ultrasonic source combined with a rectangle vibrating plate and rigid walls -- study of the aerial capacity of ultrasonic standing wave field --
Ryo Sato, Takuya Asami, Hikaru Miura (Nihon Univ.) US2016-67
An apparatus, to form intensity ultrasonic standing wave field using sound wave radiated from the ultrasonic source, has... [more] US2016-67
pp.35-40
US, EA
(Joint)
2016-01-29
09:25
Osaka Kansai University, Centenary Memorial Hall Ultrasonic atomization using circular vibrating plate with hollow
Ryo Yakou, Takuya Asami, Hikaru Miura (Nihon Univ.) US2015-94
 [more] US2015-94
pp.61-66
US 2015-12-21
13:30
Tokyo Surugadai Campus, Nihon University Focusing sound field by ultrasonic source combined circular vibrating plate with cylindrical rigid wall
Yuta Sibanai, Takuya Asami, Hikaru Miura (Nihon Univ.) US2015-74
In order to use a sound source and several reflective elements, apparatus for focusing acoustic waves emitted from the u... [more] US2015-74
pp.1-6
US 2015-12-21
14:45
Tokyo Surugadai Campus, Nihon University Ultrasonic complex vibration source consisted of longitudinal vibration and torsional vibration transducers
Takuya Asami, Hikaru Miura (Nihon Univ.) US2015-77
We think that the planar vibration locus is available to ultrasonic vibration assisted manufacturing technology. In prev... [more] US2015-77
pp.19-22
US 2015-05-25
13:30
Tokyo Kikai-Shinko-Kaikan Bldg. Study of particle size of non-contact atomization droplet by intense ultrasonic source.
Arisa Endo, Takuya Asami, Hikaru Miura (Nihon Univ.) US2015-9
Atomization is required by the mass analyzer which is a device for performing the component analysis of the liquid. Ther... [more] US2015-9
pp.1-5
US 2014-12-15
13:55
Tokyo Tokyo Institute of Technology, Suzukakedai Campus Formation of aerial standing wave field using ultrasonic sources employing four stripe-mode vibrating plates with a jut driving point
Koki Naito, Takuya Asami, Hikaru Miura (Nihon Univ.) US2014-66
An ultrasonic source using a stripe-mode rectangular transverse vibrating plate radiates strong acoustic waves in the ai... [more] US2014-66
pp.5-10
US 2014-12-15
14:20
Tokyo Tokyo Institute of Technology, Suzukakedai Campus Ultrasonic Metal Welding of Dissimilar Metals by Planar Vibration Locus -- Relationship between weld strength and weld area --
Takuya Asami, Daiki Saito, Kei Sugiyama, Hikaru Miura (Nihon Univ.) US2014-67
Metal welding of dissimilar metals and low-resistance metals are difficult by the resistance welding. Thus, ultrasonic m... [more] US2014-67
pp.11-16
CQ 2014-07-10
14:30
Osaka   [Poster Presentation] The Effect of Re-acceleration Process on Multi-channel Acoustic Echo Canceler Using Particle Swarm Optimization
Takuya Asami, Masanori Kimoto, Takefumi Hiraguri (Nippon Inst. of Tech.) CQ2014-28
In multichannel acoustic echo canceler based on linear combination, the uniqueness problem exists that
adaptive filt... [more]
CQ2014-28
pp.71-75
 Results 21 - 40 of 51 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan