Fukuoka |
|
Experimental Verification of A Voltage clamp ZVS-PWM Bidirectional DC-DC Converter Masahiro Kitagawa, Koji Fujiwara, Yoshiyuki Ishihara (Doshisha Univ.), Masashi Ogura, Yoshifumi Minowa, Nobuhiro Kurio (Nissin Electric) EE2009-46 |
This paper proposes an isolated bidirectional DC-DC converter that is suitable for use in a low-voltage, large-current b... [more] |
EE2009-46 pp.59-64 |
EMCJ |
2010-01-21 15:05 |
Okinawa |
University of the Ryukyus |
Leaked Emissions due to the In-House Broadband Powerline Communications (2)
-- Measurements by HF Radio Astronomy Antennas -- Masatoshi Ohishi (National Astronomical Observatory of Japan), Masahiro Kitagawa (Osaka Univ.), Hiroaki Misawa, Fuminori Tsuchiya (Tohoku Univ.) EMCJ2009-108 |
There have been the concerns that the Japanese broadband Power Line Communications (PLC) may cause harmful interference ... [more] |
EMCJ2009-108 pp.57-62 |
EMCJ |
2010-01-21 15:30 |
Okinawa |
University of the Ryukyus |
Fatal erros in technical criteria for broadband power-line communications in Japan Masahiro Kitagawa (Osaka Univ.) EMCJ2009-109 |
[more] |
EMCJ2009-109 pp.63-68 |
EMCJ |
2009-09-04 11:15 |
Kyoto |
KEIHANNA PLAZA |
Leaked Emissions due to the In-House Broadband Powerline Communications (1)
-- Measurements of the Electric Field Strength at a Distance and Direct Measurements of the Common-Mode Current -- Masatoshi Ohishi (NAOJ), Masahiro Kitagawa, Hiroaki Misawa, Fuminori Tsuchiya (Osaka Uhiv.) EMCJ2009-40 |
Measurements on the leaked electric field, when the in-house broadband power line communication (PLC) devices are in use... [more] |
EMCJ2009-40 pp.29-34 |
EMCJ, ITE-BCT |
2009-03-13 11:00 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Loophole in the Measurement of Conducted Emission from Broadband Power-Line Communications using Impedance Stabilization Network Masahiro Kitagawa (Osaka Univ.) EMCJ2008-115 |
The radiated emission due to the in-house broadband power-line communications (PLC) is caused by the common-mode (CM) cu... [more] |
EMCJ2008-115 pp.7-12 |
EMCJ |
2008-11-20 16:45 |
Tokyo |
AIST Tokyo Waterfront |
Hidden antenna current in domestic power-line network Masahiro Kitagawa (Osaka univ) EMCJ2008-78 |
he common-mode (CM) current generated from the differential-mode
(DM) signal at the unbalanced elements distributed on ... [more] |
EMCJ2008-78 pp.21-26 |
EMCJ |
2008-06-20 10:05 |
Hokkaido |
Hokkaido Univ. |
Outlet LCL does not tell the mode conversions distributed in the power-line network
-- Transmission line theory of common-mode current and LCL -- Masahiro Kitagawa (Osaka Univ.) EMCJ2008-10 |
The radiated emission from the power-line communications (PLC) is mainly caused by the common mode (CM) current converte... [more] |
EMCJ2008-10 pp.17-22 |
EMCJ |
2008-03-07 09:35 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment III Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-117 |
The radiated electric field (REF) of the in-house broadband power line communications (PLC) in Japan is supposed to be b... [more] |
EMCJ2007-117 pp.1-6 |
EMCJ, MW |
2007-10-25 09:35 |
Miyagi |
Tohoku University |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment II Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-53 MW2007-100 |
Japanese regulations of in-house broadband power line communications (PLC)
are supposed to suppress the radiated electr... [more] |
EMCJ2007-53 MW2007-100 pp.1-6 |
EMCJ, MW |
2007-10-25 10:00 |
Miyagi |
Tohoku University |
In-situ Measurement of the Antenna Factor of In-house Power Lines Masahiro Kitagawa (Osaka Univ.) EMCJ2007-54 MW2007-101 |
The in-house power line network could be relatively good antenna at MF/HF. Measurement of the antenna gain or antenna f... [more] |
EMCJ2007-54 MW2007-101 pp.7-12 |
EMCJ |
2007-09-21 14:25 |
Kyoto |
Doshisha University |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment I Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-49 |
In Japan, in-house broadband power line communications (PLC) are regulated only in terms of the common-mode current (CMI... [more] |
EMCJ2007-49 pp.37-42 |