Committee Date Time Place Paper Title / Authors Abstract Paper #
MI 2013-01-24
11:05
Okinawa Bunka Tenbusu Kan Performance improvements using MRI anatomical normalization in statistical comparison of brain FDG-PET for dementia diagnosis
Ryosuke Mizuno (Chiba Univ./TMIG), Muneyuki Sakata, Kenji Ishii, Keiichi Oda, Jun Toyohara, Kiichi Ishiwata (TMIG), Yuichi Kimura (NIRS/Chiba Univ.) MI2012-66
Statistical comparisons to detect significant decreases of glucose metabolism in brain images of positron emission tomog... [more] MI2012-66
pp.25-29
MI 2013-01-24
13:10
Okinawa Bunka Tenbusu Kan Comparison of MR Elastography and US Elastography: a Phantom Study
Atsuhisa Koyama (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Riwa Kishimoto (NIRS), Hajime Ikeda, Shinpei Shimazaki (Chiba Univ.), Tetsuya Wakayama (GEHC-J), Takayuki Obata, Hiroshi Tsuji (NIRS) MI2012-68
MR Elastography (MRE) and Ultrasound Elastography (USE) are used to quantify the storage modulus or shear wave velocity ... [more] MI2012-68
pp.33-36
MI 2013-01-24
16:00
Okinawa Bunka Tenbusu Kan Time delay correction method for PET-based tumor tracking
Tetsuya Shinaji (Chiba Univ.), Hideaki Tashima, Eiji Yoshida, Hideo Murayama, Taiga Yamaya (NIRS), Hideaki Haneishi (Chiba Univ.) MI2012-87
The world’s first open type PET, named OpenPET, is being developed at the National Institute Radiological Sciences. We a... [more] MI2012-87
pp.129-133
MI 2013-01-25
13:10
Okinawa Bunka Tenbusu Kan in-vivo Brain MR Elastography using Mechanical Vibration of the Patient Table by Vibration Induced Switching Gradient
Hajime Ikeda (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Atsuhisa Koyama, Shinpei Shimazaki (Chiba Univ.), Tetsuya Wakayama (GEHC-J), Riwa Kishimoto, Takayuki Obata (NIRS) MI2012-107
Magnetic resonance elastography (MRE) is a noninvasive method for measuring tissue quantitative elasticity. Current brai... [more] MI2012-107
pp.235-238
MI 2013-01-25
13:10
Okinawa Bunka Tenbusu Kan Influence of MRI-based attenuation correction methods on quantitative analysis of brain PET
Hiroshi Kawaguchi (NIRS), Asuka Tanigawa, Mikio Suga (Chiba Univ.), Yoshiyuki Hirano, Takahiro Shiraishi, Eiji Yoshida, Yasuyuki Kimura, Katsuyuki Tanimoto, Takayuki Obata, Hiroshi Ito, Taiga Yamaya (NIRS) MI2012-108
The quantitative capability is fundamental for PET in the human brain. Several attenuation correction methods for PET/MR... [more] MI2012-108
pp.239-244
MI 2013-01-25
13:10
Okinawa Bunka Tenbusu Kan Influence of rate constants as the prior to performance of denoising tissue time activity curves for PET kinetic analaysis
Takahiro Kozawa, Hidekata Hontani (NIT), Kazuya Sakaguchi (Kitasato Univ), Muneyuki Sakata (TMIG), Yuichi Kimura (NIRS) MI2012-117
A Bayesian approach to de-noise tissue time activity curves (tTAC) is proposed. The proposed method estimate the posteri... [more] MI2012-117
pp.287-292
MI 2012-07-19
15:40
Yamagata Yamagata Univ. Bayesian Inference Approach to Visualize Neuroreceptor Density using Positron Emission Tomography without Arterial Blood Sampling
Takahiro Kozawa, Hidekata Hontani (NIT), Kazuya Sakaguchi (Kitasato Univ), Muneyuki Sakata (TMGHIG), Yuichi Kimura (NIRS) MI2012-26
A Bayesian approach to de-noise tissue time activity curves (tTAC) is proposed in order to quantitatively visualize neur... [more] MI2012-26
pp.29-34
MI 2012-01-19
10:30
Okinawa   Bayesian Approach for the Denoising to PET Dynamic Data without Arterial Blood Sampling
Takahiro Kozawa, Hidekata Hontani (NIT), Kazuya Sakaguchi (Kitasato Univ), Muneyuki Sakata (TMGHIG), Yuichi Kimura (NIRS) MI2011-79
In this report, we propose a new method for denoising tissue time activity curve (tTAC) measured from brain PET images. ... [more] MI2011-79
pp.11-16
MI 2012-01-20
11:25
Okinawa   GPU-Based Simulation of optical photons in Laser-processed crystal block of PET detector
Yuma Ogata (Chiba Univ.), Takahiro Moriya (Hamamatsu Photonics K.K.), Naoko Inadama, Fumihiko Nishikido, Eiji Yoshida, Hideo Murayama, Taiga Yamaya (NIRS), Hideaki Haneishi (Chiba Univ.) MI2011-124
 [more] MI2011-124
pp.257-261
MI 2012-01-20
15:35
Okinawa   Validation of Spatio-temporal Reconstruction Algorithm Based on DRAMA Using Small Animal Dynamic PET Data
Tatsuya Kon, Takashi Obi, Nagaaki Ohyama (Tokyo Inst. of Tech.), Yuichi Kimura (National Inst. of Radiological Sci.) MI2011-155
The accuracy of the estimated parametric images is largely dependent on that of the tissue time activity curves (tTACs.)... [more] MI2011-155
pp.431-435
MI 2012-01-20
15:50
Okinawa   The 2nd generation OpenPET geometry for joint cancer therapy imaging
Shoko Kinouchi (Chiba Univ./NIRS), Taiga Yamaya, Hideaki Tashima, Yoshiyuki Hirano, Eiji Yoshida, Fumihiko Nishikido (NIRS), Hideaki Haneishi, Mikio Suga (Chiba Univ.) MI2011-156
One of the challenging applications of positron emission tomography (PET) is in situ monitoring of the irradiation field... [more] MI2011-156
pp.437-439
MI 2011-09-06
10:20
Ibaraki AIST Development of Actuator for MR Elastography toward High-Resolution Viscoelasticity Measurement
Shinya Ozawa (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Hajime Ikeda, Atsuhisa Koyama (Chiba Univ.), Tetsuya Wakayama (GEHCJ), Takayuki Obata (NIRS) MI2011-50
Magnetic Resonance Elastography (MRE) is a method to visualize local viscoelastic modulus from wave motion images in tis... [more] MI2011-50
pp.17-20
MI 2011-01-20
10:15
Okinawa Naha-Bunka-Tembusu Preliminary study of in-vivo liver measurement by optimized pulse sequence for MR elastography
Ken Arai (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Shinya Ozawa, Hajime Ikeda (Chiba Univ.), Masaya Hirano (GEHC-JP), Etsuko Kobayashi (Tokyo Univ.), Takayuki Obata (NIRS) MI2010-89
Magnetic resonance elastography (MRE) is a technique for quantitative and noninvasive assessment of tissue elasticity. M... [more] MI2010-89
pp.47-50
MI 2010-01-28
09:55
Okinawa Naha-Bunka-Tenbusu Determination of starting time for graphical analysis using X-square test in PET receptor imaging
Hiroto Ogaki (Chiba Univ/NIRS), Kazuya Sakaguchi (NIRS), Mikio Suga (Chiba Univ/NIRS), Yuichi Kimura (NIRS/Chiba Univ) MI2009-75
This study aims at developing an algorithm to estimate a starting point, t*, for Logan Graphical Analysis (LGA) and Mult... [more] MI2009-75
pp.1-6
MI 2010-01-28
10:05
Okinawa Naha-Bunka-Tenbusu A Strategy to Improve PET Neuroreceptor Analysis MA1 Based on Statistics of Measurement Errors
Naoki Hoshino, Hidekata Hontani (Nagoya Inst. of Tech.), Mika Naganawa, Kazuya Sakaguchi (National Inst. of Radiological Sci.), Muneyuki Sakata, Kiichi Ishiwata (Tokyo Metro Inst. of Gerontology), Yuichi Kimura (National Inst. of Radiological Sci.) MI2009-76
In this article, we propose a new method for improving MA1, which
estimates total distribution volume $V_{\rm T}$, the ... [more]
MI2009-76
pp.7-12
MI 2010-01-28
11:05
Okinawa Naha-Bunka-Tenbusu Simplification of the patient set up in radiotherapy with guideline using epipolar geometry
Riki Fukuhara (Chiba Univ.), Shinichiro Mori, Motoki Kumagai (National Inst. of Radiological Sci.), Hideaki Haneishi (Chiba Univ.) MI2009-81
It is necessary to perform patient set up accurately in radiotherapy. Generally the radiotherapy is performed repeatedly... [more] MI2009-81
pp.37-40
MI 2010-01-28
11:40
Okinawa Naha-Bunka-Tenbusu Estimation algorithm using direct search method in PET neuroreceptor quantification
Yosuke Okanishi (Chiba Univ.), Yuichi Kimura, Mikio Suga (National Inst. of Radiological Sci./Chiba Univ.) MI2009-84
In a compartment model analysis using positron emission tomography (PET), some problems arises in non-linear estimation:... [more] MI2009-84
pp.53-56
MI 2010-01-28
11:40
Okinawa Naha-Bunka-Tenbusu Implementation of list-mode PET reconstruction using GPU
Shoko Kinouchi (Chiba Univ./National Inst. of Radiological Sci.), Taiga Yamaya, Eiji Yoshida (National Inst. of Radiological Sci.), Mikio Suga (Chiba Univ.) MI2009-85
We developed a 3D list-mode iterative image reconstruction using GPU. The efficiency of acceleration depends on the impl... [more] MI2009-85
pp.57-60
MI 2010-01-28
11:40
Okinawa Naha-Bunka-Tenbusu Development of the Next Supporting System for a Radiation Treatment Planning System -- Evaluation of Nonlinear Registration using 3D Free Form Deformation --
Takumi Tanikawa, Yutaka Ando (National Inst. of Radiological Sci.), Koji Uemura (Kawasaki University of Medical Welfare), Masami Mukai (National Inst. of Radiological Sci.), Takashi Masuzawa, Masakazu Osada (Toshiba Medical), Nobuhiro Tsukamoto (Saitama Medical Univ.), Osamu Kawaguchi (Keio Univ.) MI2009-92
The three-dimensional free form deformation (3D-FFD) method was studied for the registration of CT images. The purpose o... [more] MI2009-92
pp.93-96
MI 2010-01-29
11:40
Okinawa Naha-Bunka-Tenbusu [Poster Presentation] Comparison of Inversion Algorithm for Magnetic Resonance Elastography -- Availability for Focused Acoustic Driver --
Hisayuki Miura, Mikio Suga (Chiba Univ.), Hiroshi Fujiwara (Kyoto Univ.), Takao Yamamoto (Gunma Univ.), Masaya Hirano (GE Healthcare Japan), Hiroo Ikehira, Takayuki Obata (National Inst. of Radiological Sci.) MI2009-142
The stiffness of tissue is related to physiological and pathological state. Magnetic resonance elastography (MRE) is a t... [more] MI2009-142
pp.357-360
 Results 21 - 40 of 59 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)