講演抄録/キーワード |
講演名 |
2014-11-30 09:30
[招待講演]Correlation between load current mode and contact resistance of a closed pair of contacts ○Wanbin Ren・Hai Wang・Chenghuan Liu・Yu Chen(Harbin Inst. of Tech.)・Jian Song(OWL Univ. of Applied Sciences) EMD2014-81 エレソ技報アーカイブへのリンク:EMD2014-81 |
抄録 |
(和) |
The electrical contact resistance of closed contact pair is dependent on contact material physical characteristics, contact type (sphere-flat or flat-flat), contact surface status (clean or contaminated), but also contact current and mechanical load during measuring. The relationships between contact resistance and load current and load force with the use of DC mode and non-constant current mode measurement method are compared in this paper. The variations in thermoelectric voltage of contact pairs as a function of time with constant force load are presented. |
(英) |
The electrical contact resistance of closed contact pair is dependent on contact material physical characteristics, contact type (sphere-flat or flat-flat), contact surface status (clean or contaminated), but also contact current and mechanical load during measuring. The relationships between contact resistance and load current and load force with the use of DC mode and non-constant current mode measurement method are compared in this paper. The variations in thermoelectric voltage of contact pairs as a function of time with constant force load are presented. |
キーワード |
(和) |
Contact resistance / measurement / load current / Delta mode / thermoelectric voltage / / / |
(英) |
Contact resistance / measurement / load current / Delta mode / thermoelectric voltage / / / |
文献情報 |
信学技報, vol. 114, no. 342, EMD2014-81, pp. 93-98, 2014年11月. |
資料番号 |
EMD2014-81 |
発行日 |
2014-11-22 (EMD) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
著作権に ついて |
技術研究報告に掲載された論文の著作権は電子情報通信学会に帰属します.(許諾番号:10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
PDFダウンロード |
EMD2014-81 エレソ技報アーカイブへのリンク:EMD2014-81 |