Paper Abstract and Keywords |
Presentation |
2014-03-18 09:20
Evaluation of SWFIT sequence for magnetic resonance signal from hyperpolarized 129Xe Kazuhiro Nakamura, Yasushi Kondoh, Toshibumi Kinoshita (Akita Noken) MBE2013-131 |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
Sweep imaging with Fourier transformation(SWIFT) is novel MRI sequence with swept radiofrequency (RF) excitation of amplitude and frequency modulation. Spatial-encoding is prepared by swept RF instead of the pulsed field gradient in SWIFT. It was minimized gradient signal loss especially for hyperpolarized xenon gas with large diffusion constant. We have investigated optimized parameter of SWIFT sequence with computer simulation of Bloch equation |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
SWIFT / MRI / Hyperpolarized xenon gas / / / / / |
Reference Info. |
IEICE Tech. Rep., vol. 113, no. 499, MBE2013-131, pp. 85-90, March 2014. |
Paper # |
MBE2013-131 |
Date of Issue |
2014-03-10 (MBE) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
Download PDF |
MBE2013-131 |
Conference Information |
Committee |
NC MBE |
Conference Date |
2014-03-17 - 2014-03-18 |
Place (in Japanese) |
(See Japanese page) |
Place (in English) |
Tamagawa University |
Topics (in Japanese) |
(See Japanese page) |
Topics (in English) |
|
Paper Information |
Registration To |
MBE |
Conference Code |
2014-03-NC-MBE |
Language |
Japanese |
Title (in Japanese) |
(See Japanese page) |
Sub Title (in Japanese) |
(See Japanese page) |
Title (in English) |
Evaluation of SWFIT sequence for magnetic resonance signal from hyperpolarized 129Xe |
Sub Title (in English) |
|
Keyword(1) |
SWIFT |
Keyword(2) |
MRI |
Keyword(3) |
Hyperpolarized xenon gas |
Keyword(4) |
|
Keyword(5) |
|
Keyword(6) |
|
Keyword(7) |
|
Keyword(8) |
|
1st Author's Name |
Kazuhiro Nakamura |
1st Author's Affiliation |
Akita Research Institute for Brain and Blood Vessels (Akita Noken) |
2nd Author's Name |
Yasushi Kondoh |
2nd Author's Affiliation |
Akita Research Institute for Brain and Blood Vessels (Akita Noken) |
3rd Author's Name |
Toshibumi Kinoshita |
3rd Author's Affiliation |
Akita Research Institute for Brain and Blood Vessels (Akita Noken) |
4th Author's Name |
|
4th Author's Affiliation |
() |
5th Author's Name |
|
5th Author's Affiliation |
() |
6th Author's Name |
|
6th Author's Affiliation |
() |
7th Author's Name |
|
7th Author's Affiliation |
() |
8th Author's Name |
|
8th Author's Affiliation |
() |
9th Author's Name |
|
9th Author's Affiliation |
() |
10th Author's Name |
|
10th Author's Affiliation |
() |
11th Author's Name |
|
11th Author's Affiliation |
() |
12th Author's Name |
|
12th Author's Affiliation |
() |
13th Author's Name |
|
13th Author's Affiliation |
() |
14th Author's Name |
|
14th Author's Affiliation |
() |
15th Author's Name |
|
15th Author's Affiliation |
() |
16th Author's Name |
|
16th Author's Affiliation |
() |
17th Author's Name |
|
17th Author's Affiliation |
() |
18th Author's Name |
|
18th Author's Affiliation |
() |
19th Author's Name |
|
19th Author's Affiliation |
() |
20th Author's Name |
|
20th Author's Affiliation |
() |
Speaker |
Author-1 |
Date Time |
2014-03-18 09:20:00 |
Presentation Time |
20 minutes |
Registration for |
MBE |
Paper # |
MBE2013-131 |
Volume (vol) |
vol.113 |
Number (no) |
no.499 |
Page |
pp.85-90 |
#Pages |
6 |
Date of Issue |
2014-03-10 (MBE) |