Research on the Influence of Contact gap on AC Arc Duration of Electromagnetic Relay ○Xuerong Ye・Zhao Han・Xinglei Cui・Huimin Liang・Guofu Zhai(Harbin Inst. of Tech.) EMD2013-95 エレソ技報アーカイブへのリンク:EMD2013-95 |
抄録 |
(和) |
AC arc generated during the electromagnetic relay (EMR) action process under AC load will cause the contact erosion and shorten the life time of relay. The increasing of contact gap is favorable for extinguishment of the AC arc, but it will also result in the increasing of magnetic gap, which may further influence the electromagnetic force and the dynamic features of the relay. In this paper, a certain type of AC loaded EMR is studied. Firstly, the relationship between contact gap and AC arc duration is analyzed, which can provide the theoretical basis for the optimization of contact gap. Then, limiting conditions of optimizing the relay contact gap is determined by real arc experiment of different contact gap, and considering such limiting factors as actual product dimension and processing process, finally obtains the optimization solution. In the end, the optimization results for the relay are verified by the real product complete-period life test. |
(英) |
AC arc generated during the electromagnetic relay (EMR) action process under AC load will cause the contact erosion and shorten the life time of relay. The increasing of contact gap is favorable for extinguishment of the AC arc, but it will also result in the increasing of magnetic gap, which may further influence the electromagnetic force and the dynamic features of the relay. In this paper, a certain type of AC loaded EMR is studied. Firstly, the relationship between contact gap and AC arc duration is analyzed, which can provide the theoretical basis for the optimization of contact gap. Then, limiting conditions of optimizing the relay contact gap is determined by real arc experiment of different contact gap, and considering such limiting factors as actual product dimension and processing process, finally obtains the optimization solution. In the end, the optimization results for the relay are verified by the real product complete-period life test. |
キーワード |
(和) |
electromagnetic relay / AC arc / contact gap / optimization / / / / |
(英) |
electromagnetic relay / AC arc / contact gap / optimization / / / / |
文献情報 |
信学技報, vol. 113, no. 298, EMD2013-95, pp. 83-86, 2013年11月. |
資料番号 |
EMD2013-95 |
発行日 |
2013-11-09 (EMD) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
著作権に ついて |
技術研究報告に掲載された論文の著作権は電子情報通信学会に帰属します.(許諾番号:10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
PDFダウンロード |
EMD2013-95 エレソ技報アーカイブへのリンク:EMD2013-95 |