V-I characteristics of Arcs is needed to properly analyze electrical circuits that include arc discharge. Guye’s research on V-I characteristics of arcs between copper electrodes concerns currents of 2 amperes to 20 amperes and lengths of arcs varying from 0mm to 4mm. His research however, does not include currents lower than 2 amperes. Our research aims at deriving the V-I characteristics of arcs between copper electrodes when the current is lower than 2 amperes by using moving contacts. We also go a step further and investigate the extinction characteristics when the arc is unstable. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
arc discharge / copper arc / V-I characteristics / extinction characteristics / length between electrodes / / / |
Reference Info. |
IEICE Tech. Rep., vol. 111, no. 460, EMD2011-130, pp. 17-20, March 2012. |
Paper # |
EMD2011-130 |
Date of Issue |
2012-02-24 (EMD) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
Download PDF |
EMD2011-130 Link to ES Tech. Rep. Archives: EMD2011-130 |
Conference Information |
Committee |
EMD |
Conference Date |
2012-03-02 - 2012-03-02 |
Place (in Japanese) |
(See Japanese page) |
Place (in English) |
Tanagawa Univ. |
Topics (in Japanese) |
(See Japanese page) |
Topics (in English) |
|
Paper Information |
Registration To |
EMD |
Conference Code |
2012-03-EMD |
Language |
Japanese |
Title (in Japanese) |
(See Japanese page) |
Sub Title (in Japanese) |
(See Japanese page) |
Title (in English) |
V-I Characteristics and Extinction Characteristics of Arcs between Copper Electrodes |
Sub Title (in English) |
|
Keyword(1) |
arc discharge |
Keyword(2) |
copper arc |
Keyword(3) |
V-I characteristics |
Keyword(4) |
extinction characteristics |
Keyword(5) |
length between electrodes |
Keyword(6) |
|
Keyword(7) |
|
Keyword(8) |
|
1st Author's Name |
Godwill Mbiti |
1st Author's Affiliation |
Tokyo National College of Technology (TNCT) |
2nd Author's Name |
Keiichi Suhara |
2nd Author's Affiliation |
Tokyo National College of Technology (TNCT) |
3rd Author's Name |
|
3rd Author's Affiliation |
() |
4th Author's Name |
|
4th Author's Affiliation |
() |
5th Author's Name |
|
5th Author's Affiliation |
() |
6th Author's Name |
|
6th Author's Affiliation |
() |
7th Author's Name |
|
7th Author's Affiliation |
() |
8th Author's Name |
|
8th Author's Affiliation |
() |
9th Author's Name |
|
9th Author's Affiliation |
() |
10th Author's Name |
|
10th Author's Affiliation |
() |
11th Author's Name |
|
11th Author's Affiliation |
() |
12th Author's Name |
|
12th Author's Affiliation |
() |
13th Author's Name |
|
13th Author's Affiliation |
() |
14th Author's Name |
|
14th Author's Affiliation |
() |
15th Author's Name |
|
15th Author's Affiliation |
() |
16th Author's Name |
|
16th Author's Affiliation |
() |
17th Author's Name |
|
17th Author's Affiliation |
() |
18th Author's Name |
|
18th Author's Affiliation |
() |
19th Author's Name |
|
19th Author's Affiliation |
() |
20th Author's Name |
|
20th Author's Affiliation |
() |
Speaker |
Author-1 |
Date Time |
2012-03-02 13:30:00 |
Presentation Time |
15 minutes |
Registration for |
EMD |
Paper # |
EMD2011-130 |
Volume (vol) |
vol.111 |
Number (no) |
no.460 |
Page |
pp.17-20 |
#Pages |
4 |
Date of Issue |
2012-02-24 (EMD) |