Liver image registration with constraint applied for accurate tumor localization
Duhgoon Lee, Woo Hyun Nam, Jong Beom Ra (KAIST)
Abstract (in Japanese) (See Japanese page) 
(in English) The main purpose of liver image registration of 3D ultrasound and XCT images is in accurate tumor localization in an US image by fusing the corresponding XCT image. The existing approach for US-XCT liver registration aims to align visible anatomical structures such as vessels and diaphragm between two images. In this paper, we try to improve the performance of non-rigid registration for accurate tumor localization. By examining the motions of tumors, vessels, and diaphragm and adopting thin-plate spline modeling of vessels, we apply a constraint to the non-rigid transformation. Experimental results show the improvement of registration accuracy in tumor area.
Keyword (in Japanese) (See Japanese page) 
(in English) liver / ultrasound / XCT / non-rigid registration / tumor localization / / /  
Reference Info. IEICE Tech. Rep., vol. 108, no. 385, MI2008-68, pp. 47-48, Jan. 2009.
Paper # MI2008-68 
Date of Issue 2009-01-12 (MI) 
ISSN Print edition: ISSN 0913-5685  Online edition: ISSN 2432-6380

Conference Information
Committee MI  
Conference Date 2009-01-19 - 2009-01-21 
Place (in Japanese) (See Japanese page) 
Place (in English) National Taiwan University 
Topics (in Japanese) (See Japanese page) 
Topics (in English) Medical Imaging 
Paper Information
Registration To MI 
Conference Code 2009-01-MI 
Language English 
Title (in Japanese) (See Japanese page) 
Sub Title (in Japanese) (See Japanese page) 
Title (in English) Liver image registration with constraint applied for accurate tumor localization 
Sub Title (in English)  
Keyword(1) liver  
Keyword(2) ultrasound  
Keyword(3) XCT  
Keyword(4) non-rigid registration  
Keyword(5) tumor localization  
Keyword(6)  
Keyword(7)  
Keyword(8)  
1st Author's Name Duhgoon Lee  
1st Author's Affiliation KAIST (KAIST)
2nd Author's Name Woo Hyun Nam  
2nd Author's Affiliation KAIST (KAIST)
3rd Author's Name Jong Beom Ra  
3rd Author's Affiliation KAIST (KAIST)
4th Author's Name  
4th Author's Affiliation ()
5th Author's Name  
5th Author's Affiliation ()
6th Author's Name  
6th Author's Affiliation ()
7th Author's Name  
7th Author's Affiliation ()
8th Author's Name  
8th Author's Affiliation ()
9th Author's Name  
9th Author's Affiliation ()
10th Author's Name  
10th Author's Affiliation ()
11th Author's Name  
11th Author's Affiliation ()
12th Author's Name  
12th Author's Affiliation ()
13th Author's Name  
13th Author's Affiliation ()
14th Author's Name  
14th Author's Affiliation ()
15th Author's Name  
15th Author's Affiliation ()
16th Author's Name  
16th Author's Affiliation ()
17th Author's Name  
17th Author's Affiliation ()
18th Author's Name  
18th Author's Affiliation ()
19th Author's Name  
19th Author's Affiliation ()
20th Author's Name  
20th Author's Affiliation ()
Speaker
Date Time 2009-01-19 14:25:00 
Presentation Time 10 
Registration for MI 
Paper # IEICE-MI2008-68 
Volume (vol) IEICE-108 
Number (no) no.385 
Page pp.47-48 
#Pages IEICE-2 
Date of Issue IEICE-MI-2009-01-12 


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan