Research on the electromagnetic compatibility of functional module composed of two independent electromagnetic relays in a hermetically sealed shell is the technical foundation for integration and miniaturization of electronic equipment in the future. In this paper, 3D finite element method (FEM) was used to analyze the dynamic characteristics of twin-type relay interfered by uniform constant magnetic field and identify the sensitive direction in which the relay was easily interfered. The models of twin-type relay in three working states were founded. Through simulation and analysis, it was found out how the operation time and electromagnetic torque of twin-type relay changed with the outer interfered magnetic field. When the relay was on the point of operation failure, the critical value of magnetic field was calculated through simulation. The simulation results of the dynamic characteristics of twin-type relay agree well with the experimental data. The conclusion in this paper is of great value for research on the electromagnetic compatibility of relay functional model. |
(英) |
Research on the electromagnetic compatibility of functional module composed of two independent electromagnetic relays in a hermetically sealed shell is the technical foundation for integration and miniaturization of electronic equipment in the future. In this paper, 3D finite element method (FEM) was used to analyze the dynamic characteristics of twin-type relay interfered by uniform constant magnetic field and identify the sensitive direction in which the relay was easily interfered. The models of twin-type relay in three working states were founded. Through simulation and analysis, it was found out how the operation time and electromagnetic torque of twin-type relay changed with the outer interfered magnetic field. When the relay was on the point of operation failure, the critical value of magnetic field was calculated through simulation. The simulation results of the dynamic characteristics of twin-type relay agree well with the experimental data. The conclusion in this paper is of great value for research on the electromagnetic compatibility of relay functional model. |
キーワード |
(和) |
twin-type relay / uniform constant magnetic field / functional model / operation time / electromagnetic compatibility / / / |
(英) |
twin-type relay / uniform constant magnetic field / functional model / operation time / electromagnetic compatibility / / / |
文献情報 |
信学技報, vol. 107, no. 309, EMD2007-92, pp. 137-142, 2007年11月. |
資料番号 |
EMD2007-92 |
発行日 |
2007-11-07 (EMD) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
著作権に ついて |
技術研究報告に掲載された論文の著作権は電子情報通信学会に帰属します.(許諾番号:10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
PDFダウンロード |
EMD2007-92 エレソ技報アーカイブへのリンク:EMD2007-92 |