Closed bellows pressure sensor telemeter transmitter for unconstrained continuous monitoring of intracorporeal pressure Koya Nakazono (Kagoshima Univ.), Seiji Matsumoto, Hirotsugu Uemura (Kinki Univ.), Yasuhito Takeuchi (Kagoshima Univ.) |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
Abstract: Noninvasive, non-disturbing urodynamics study still has many unsolved burdens since urinal accumulation and voiding process is very sensitive for disturbances in variety of sense. Here in this study an intra-bladder encapsulated pressure sensor telemeter transmitter is designed and prototyped for in-vitro and in-vivo feasibility study. A pressure sensitive variable inductor, together with oscillator circuit and battery, is encapsulated in 6mm diameter container (passable through external urethra), while extra-corporeal search coil and narrow-band heterodyne receiver tracks its oscillatory signal for precise frequency or phase trajectory measurement, to make pressure trend measurement. In an in-vivo test using adult rabbit, the system successfully measured the process of urination reflex followed by natural voiding, for many times during hours of observation time. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
bladder / pressure / telemetry / capsule / search coil / urodynamics / Noninvasive / voiding |
Reference Info. |
IEICE Tech. Rep., vol. 106, no. 506, MBE2006-117, pp. 85-88, Jan. 2007. |
Paper # |
MBE2006-117 |
Date of Issue |
2007-01-19 (MBE) |
ISSN |
Print edition: ISSN 0913-5685 |
Download PDF |
|
Conference Information |
Committee |
MBE |
Conference Date |
2007-01-26 - 2007-01-26 |
Place (in Japanese) |
(See Japanese page) |
Place (in English) |
Kagoshima-Shichoson-Jichi-Kaikan Bldg. |
Topics (in Japanese) |
(See Japanese page) |
Topics (in English) |
|
Paper Information |
Registration To |
MBE |
Conference Code |
2007-01-MBE |
Language |
Japanese |
Title (in Japanese) |
(See Japanese page) |
Sub Title (in Japanese) |
(See Japanese page) |
Title (in English) |
Closed bellows pressure sensor telemeter transmitter for unconstrained continuous monitoring of intracorporeal pressure |
Sub Title (in English) |
|
Keyword(1) |
bladder |
Keyword(2) |
pressure |
Keyword(3) |
telemetry |
Keyword(4) |
capsule |
Keyword(5) |
search coil |
Keyword(6) |
urodynamics |
Keyword(7) |
Noninvasive |
Keyword(8) |
voiding |
1st Author's Name |
Koya Nakazono |
1st Author's Affiliation |
Kagoshima University (Kagoshima Univ.) |
2nd Author's Name |
Seiji Matsumoto |
2nd Author's Affiliation |
Kinki University (Kinki Univ.) |
3rd Author's Name |
Hirotsugu Uemura |
3rd Author's Affiliation |
Kinki University (Kinki Univ.) |
4th Author's Name |
Yasuhito Takeuchi |
4th Author's Affiliation |
Kagoshima University (Kagoshima Univ.) |
5th Author's Name |
|
5th Author's Affiliation |
() |
6th Author's Name |
|
6th Author's Affiliation |
() |
7th Author's Name |
|
7th Author's Affiliation |
() |
8th Author's Name |
|
8th Author's Affiliation |
() |
9th Author's Name |
|
9th Author's Affiliation |
() |
10th Author's Name |
|
10th Author's Affiliation |
() |
11th Author's Name |
|
11th Author's Affiliation |
() |
12th Author's Name |
|
12th Author's Affiliation |
() |
13th Author's Name |
|
13th Author's Affiliation |
() |
14th Author's Name |
|
14th Author's Affiliation |
() |
15th Author's Name |
|
15th Author's Affiliation |
() |
16th Author's Name |
|
16th Author's Affiliation |
() |
17th Author's Name |
|
17th Author's Affiliation |
() |
18th Author's Name |
|
18th Author's Affiliation |
() |
19th Author's Name |
|
19th Author's Affiliation |
() |
20th Author's Name |
|
20th Author's Affiliation |
() |
Speaker |
Author-1 |
Date Time |
2007-01-26 17:40:00 |
Presentation Time |
20 minutes |
Registration for |
MBE |
Paper # |
MBE2006-117 |
Volume (vol) |
vol.106 |
Number (no) |
no.506 |
Page |
pp.85-88 |
#Pages |
4 |
Date of Issue |
2007-01-19 (MBE) |
|