Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
AP |
2024-03-14 15:15 |
Fukui |
UNIVERSITY OF FUKUI (Primary: On-site, Secondary: Online) |
[Invited Talk (Young Researcher)]
Study of non-contact PIM measurement systems for balanced transmission lines with electrically equivalent characteristics to microstrip lines Ryunosuke Murofushi (Yokohama Natl. Univ./Polytechnic Univ.), Nobuhiro Kuga (Yokohama Natl. Univ.), Eiji Hanayama (Polytechnic Univ.) AP2023-209 |
In many communication systems, passive intermoduration (PIM) is known as one of noises. The termination method standardi... [more] |
AP2023-209 pp.45-50 |
CNR, BioX |
2024-02-29 13:30 |
Tokyo |
NHK Science & Technology Research Laboratories (Primary: On-site, Secondary: Online) |
Design of Aerial dialing PIN code input authentication system using deep learning hand shape authentication Jun Wang, Bo Wu, Kiminori Sato (TUT) BioX2023-70 CNR2023-37 |
With the continuous development of modern technology, the demand for contactless authentication is increasing, and a sim... [more] |
BioX2023-70 CNR2023-37 pp.1-6 |
US |
2023-11-27 14:10 |
Shizuoka |
Shizuoka University |
Acoustic Manipulation in Air Using Small Sound Sources Nozomu Hashiba (AIT), Masahiro Toyoda (Honda Elec.), Shin-ichi Hatanaka (Utsunomiya Univ.), Teruyuki Kozuka (AIT) US2023-50 |
Small-scale acoustic manipulation was attempted to manipulate a small object in the air. Three small sound source units ... [more] |
US2023-50 pp.40-43 |
EST, MW, EMT, OPE, MWPTHz, IEE-EMT [detail] |
2023-07-21 14:25 |
Hokkaido |
Muroran Institute of Technology (Primary: On-site, Secondary: Online) |
Study of measurable distances in vital sign sensing using millimeter-wave radar Itsuki Iwata, Yuji Tanaka, Sakamoto Takuya (Kyoto Univ.) EMT2023-58 MW2023-76 OPE2023-58 EST2023-58 MWPTHz2023-54 |
Radar-based physiological measurement techniques detect the displacement of the body surface caused by respiration and h... [more] |
EMT2023-58 MW2023-76 OPE2023-58 EST2023-58 MWPTHz2023-54 pp.249-254 |
US |
2023-06-16 15:00 |
Kyoto |
Muromachi Campus, Doshisha University |
Ultrasonic Micro-Displacement Measurement System with Thermophone for Non-Contact Cardiac Pulse Monitoring Takaaki Asada, Shinichi Sasaki, Yuma Watabe (Murata Mfg. Co., Ltd.) US2023-13 |
Non-contact vital sign monitoring is expected to be used for medical applications or driver health monitoring. Airborne ... [more] |
US2023-13 pp.20-25 |
AP |
2023-04-14 13:20 |
Osaka |
Osaka Univ. (Primary: On-site, Secondary: Online) |
Evaluation of PIM correlation between the impedance matched method and the without termination method by using coupling compensation of transmission lines Ryunosuke Murofushi (YNU/PTU), Nobuhiro Kuga (YNU), Eiji Hanayama (PTU) AP2023-3 |
Without termination method is effective to reduce system size although PIM measurement is usually carried out by using I... [more] |
AP2023-3 pp.11-15 |
SANE, SAT (Joint) |
2023-03-03 09:30 |
Okinawa |
(Primary: On-site, Secondary: Online) |
Simulation Study on Finger Position Detection Method Using Gaussian Process Regression on Non-contact Control Panels Takayuki Kitamura, Tomoya Yamaoka, Satoshi Kageme (MELCO) SANE2022-114 |
In recent years, development of transparent antennas for 5G mobile communications has been progressing, in which transpa... [more] |
SANE2022-114 pp.86-90 |
SCE |
2023-01-20 14:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Primary: On-site, Secondary: Online) |
Non-contacting Magnetostriction-Based Ultrasonic Guided Wave Testing Technique utilizing Magnetic Properties of STPG370 Pipes Yoshimi Hatsukade, Keisuke Watanabe, Kohei Okada, Ryohei Ohwa, Munkhnyam Temuulen, Wenxu Sun (Kindai Univ.) SCE2022-16 |
We have been developing a novel non-contacting magnetostriction-based ultrasonic guided wave testing technique, utilizin... [more] |
SCE2022-16 pp.17-22 |
MICT, MI |
2022-11-18 10:30 |
Aichi |
Nagoya Institute of Technology |
A Quantitative Study on AVF Thrill Using Non-Contact Measurement Takunori Shimazaki (Jikei Univ. of Health Sci.), Rumi Iwai (Hyogo Medical University Hosp.), Yoshifumi Kawakubo (Jikei Univ. of Health Sci.), Jun Mitsudou, Yuuhei Hayashi (Leimac), Shingo Ata (Osaka Met Univ.), Takeshi Yokoyama (Kyushu Univ.), Daisuke Anzai (Nagoya Tech Univ.) MICT2022-34 MI2022-63 |
An arteriovenous fistula (AVF) is a specialized vessel created by anastomosing arteriovenous vessels. Hemodialysis thera... [more] |
MICT2022-34 MI2022-63 pp.1-5 |
RCC, WBS, SAT, MICT |
2022-05-25 14:30 |
Online |
Online |
Blood Flow Velocity Estimation Based on Non-Contact AVF Imaging Takunori Shimazaki, Yoshifumi Kawakubo (Jikei University of Health Sci.), Rumi Iwai (Hyogo College of Med.), Shingo Ata (Osaka City Univ.), Daisuke Anzai (Nagoya Tech Univ.) WBS2022-4 RCC2022-4 SAT2022-4 MICT2022-4 |
In hemodialysis therapy, a special vessel called arteriovenous fistula (AVF), which is surgically created by anastomosin... [more] |
WBS2022-4 RCC2022-4 SAT2022-4 MICT2022-4 pp.14-17 |
EST |
2022-05-19 15:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Primary: On-site, Secondary: Online) |
High-precision heart rate measurement for multiple people using array radar imaging and principal component analysis Itsuki Iwata, Takuya Sakamoto (Kyoto Univ.) EST2022-7 |
Millimeter-wave radar, which has a wide frequency bandwidth and a large number of array elements, has become increasingl... [more] |
EST2022-7 pp.34-37 |
MICT, EMCJ (Joint) |
2022-03-04 09:05 |
Online |
Online |
A Study on Non-contact Blood Pressure Estimation Method based on Subject Classification by Machine Learning Shuzo Ishizaka, Kohei Yamamoto, Tomoaki Ohtsuki (Keio Univ.) MICT2021-101 |
Non-contact Blood Pressure (BP) measurement is receiving a lot of interest for BP measurement on a daily basis.
To rea... [more] |
MICT2021-101 pp.1-6 |
SIS |
2022-03-04 11:30 |
Online |
Online |
Non-Contact Heart Rate Measurement based on Bispectrum Moushumi Tazen, Naoto Sasaoka, Kasumi Fujita, Yoshiharu Okamoto (Tottori Univ.) SIS2021-43 |
A Doppler radar has been acquired as a non-contact heartrate measurement method. Non-contact heartbeats measurement has ... [more] |
SIS2021-43 pp.68-71 |
EST |
2022-01-28 11:20 |
Online |
Online |
Non-contact Heart Rate Measurement Using Millimeter-wave Array Radar and Principal Component Analysis of Phase Sequence Itsuki Iwata, Takato Koda, Takuya Sakamoto (Kyoto Univ.) EST2021-84 |
In this study, we develop a novel method for the noncontact measurement of human heartbeat using ultra-wideband millimet... [more] |
EST2021-84 pp.136-139 |
NLP, MICT, MBE, NC (Joint) [detail] |
2022-01-23 11:45 |
Online |
Online |
A Novel Quantitative AVF Measurement Method Using Non-Contact Imaging Rumi Iwai (Hyogo College of Medicine), Takunori Shimazaki, Yoshifumi Kawakubo (Jikei Univ.), Masanobu Tsurumoto (Bunri Univ.), Hiroyuki Hayashi, Masaharu Tamaki (Tamaki-Aozora Hospital.), Aki Otsuka (Sugi Hospital.), Kei Fukami (Kurume Univ.), Shingo Ata (Osaka City Univ.), Daisuke Anzai (Nagoya Tech Univ.) NLP2021-125 MICT2021-100 MBE2021-86 |
Hemodialysis is a treatment where the blood is once sent out of the body and cleaned using a special filter called a dia... [more] |
NLP2021-125 MICT2021-100 MBE2021-86 pp.254-259 |
MI, MICT [detail] |
2021-11-05 13:45 |
Online |
Online |
Sleep Apnea Syndrome Detection based on Characteristics of Micro-WAKE during Sleep Iko Nakari, Keiki Takadama (UEC) MICT2021-36 MI2021-34 |
This paper describes the analysis of sequential sleep stage focused on previous and after of WAKE stage (shallow sleep) ... [more] |
MICT2021-36 MI2021-34 pp.37-42 |
MI, MICT [detail] |
2021-11-05 14:05 |
Online |
Online |
Alzheimer Dementia Detection Based on Unstable Sinusoidal Component Extracted from Circadian Rhythm of Heart Rate by Trigonometric Approximation Naoya Matsuda, Iko Nakari, Keiki Takadama (UEC) MICT2021-37 MI2021-35 |
We have proposed two Alzheimer dementia (AD) detection methods to establish a methodology using non-contact mattress sen... [more] |
MICT2021-37 MI2021-35 pp.43-48 |
HPB (2nd) |
2021-09-28 15:50 |
Online |
Online |
Fundamental Study on Measurement of Electric field Around Electric wires with Piezoelectric film Shunkichi Takamatsu (NITTC), Takaya Yoshitake (UEC), Shinichiro Mito (NITTC) |
An inexpensive non-metal-contact voltage measurement has been attracting much attention, since voltage of a commercial p... [more] |
|
HIP, VRSJ |
2021-02-19 14:45 |
Online |
Online |
[Invited Talk]
Non-contact vital sign measurement Norihiro Sugita, Makoto Yoshizawa (Tohoku Univ.) HIP2020-89 |
Pulse wave obtained from a video (video plethysmography) can be used not only for health management but also for mental ... [more] |
HIP2020-89 pp.71-72 |
US |
2020-12-14 15:15 |
Online |
Online |
Non-contact bolt loosening detection by remotely exciting a piezoelectric element bonded to a bolt Kazuhiko Hasebe, Yuji Wada, Kentaro Nakamura (Tokyo Tech) US2020-53 |
Regular inspection of bolts is important for maintaining structures, and a simple inspection method is required. A non-c... [more] |
US2020-53 pp.18-23 |