Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI |
2022-01-27 16:13 |
Online |
Online |
[Short Paper]
utomatic Extraction of Regions of Vascular Lesions Including Diffuse Lesions in MR Images Using Weakly Supervised Deep Learning Koki Fukaya, Takeshi Hara (Gifu Univ.), Taiki Nozaki, Masaki Matsusako (St.Luke's International Hosp.), Tetsuro Katafuchi (Gifu Medical Univ.), Xiangrong Zhou, Hiroshi Fujita (Gifu Univ.) MI2021-87 |
Klippel-Trenaunay-Weber syndrome (KTS) is a type of vascular lesion for which there is no quantitative diagnostic method... [more] |
MI2021-87 pp.186-187 |
MI |
2021-07-08 13:00 |
Online |
Online |
Automated detection of malignant tumors on PET/CT images using convolutional neural networks and statistical images Takumi Aihara (Gifu Univ.), Masaki Matsusako (St.Luke's International Hospital), Takeshi Hara (Gifu Univ.), Taiki Nozaki (St.Luke's International Hospital), Tetsuro Katafuchi (Gifu University of Medical Science), Satoshi Ito, Masaya Kato (Daiyukai General Hospital), Xiangrong Zhou, Hiroshi Fujita (Gifu Univ.) MI2021-9 |
In this study, we performed automatic detection of tumors from PET / CT images using Z-score images. The Z-score image i... [more] |
MI2021-9 pp.1-6 |
MI |
2020-01-29 13:20 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
[Short Paper]
Automatic segmentation of malignant tumors using PET/CT images and statistical images Manami Haga, Takeshi Hara (Gifu Univ.), Satoshi Ito, Masaya Kato (Daiyukai Hospital), Masaki Matsusako (St.Luke's Hospital), Zhou Xiangrong (Gifu Univ.), Tetsuro Katafuchi (Gifu Univ. of Medical Science), Hiroshi Fujita (Gifu Univ.) MI2019-83 |
The purpose of this study was to develop an automated detection system of tumors in FDG-PET/CT images. In this work, an ... [more] |
MI2019-83 pp.77-81 |
MI |
2020-01-30 10:50 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
[Short Paper]
Study of image quality improvement technique using deep learning for nuclear medicine images Masaya Momiuchi, Takeshi Hara (Gifu Univ), Tetsuro Katafuchi (Gifu Univ of Medical Science), Masaki Matsusako (St. Luke's Hospital), Hiroshi Fujita (Gifu Univ) MI2019-102 |
Spatial resolutions in nuclear medical imaging are not equivalent to ordinary medical images such as CT or MR modalities... [more] |
MI2019-102 pp.165-168 |
MI |
2017-01-18 14:15 |
Okinawa |
Tenbusu Naha |
[Short Paper]
Syougo Yokoi, Yuta Takeda, Takeshi Hara (Gifu Univ.), Yuki Tanaka (St. Luke's International Hospital), Tetsuro Katafuchi (Gifu Medical Science Univ.), Daisuke Fukuoka (Gifu Univ.), Taiki Nozaki, Masaki Matsusako (St. Luke's International Hospital), Hiroshi Fujita (Gifu Univ.) MI2016-91 |
(To be available after the conference date) [more] |
MI2016-91 pp.77-78 |
MI |
2017-01-18 14:15 |
Okinawa |
Tenbusu Naha |
[Short Paper]
Tomohiko Kobota, Takeshi Hara (Gifu Univ), Hiroshi Tago (Japanese Red Cross Gifu Hosp), Daisuke Fukuoka (Gifu Univ), Tetsuro Katafuchi (Gifu Univ of Medical Science), Hiroo Goto (Japanese Red Cross Gifu Hosp), Hiroshi Fujita (Gifu Univ) MI2016-93 |
(To be available after the conference date) [more] |
MI2016-93 pp.81-82 |
MI |
2015-07-14 15:40 |
Hokkaido |
Sun Refle Hakodate |
Semi-automated measurement of mean cerebral blood flow based on dynamic scintigrams Tomohiko Kobota (Gifu Univ), Hiroshi Tago (Japanese Red Cross Gifu Hosp), Takeshi Hara, Daisuke Fukuoka (Gifu Univ), Tetsuro Katafuchi (Gifu Univ of Medical Science), Hiroo Goto (Japanese Red Cross Gifu Hosp), Hiroshi Fujita (Gifu Univ) MI2015-36 |
Patlak plot法は, 脳血流シンチグラフィにおいて低侵襲な平均脳血流量(mCBF)の測定法として利用される. mCBFの値の再現性は認知症の診断に重要である. しかし手動操作による大脳半球, 大動脈弓のROIの設定は、測定値の再現性... [more] |
MI2015-36 pp.23-26 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Automated analysis of mean cerebral blood flow based on Patlak plot method Tomohiko Kobota, Takeshi Hara (Gifu Univ), Hiroshi Tago (Japanese Red Cross Gifu Hosp), Daisuke Fukuoka (Gifu Univ), Tetsuro Katafuchi (GUMS), Hiroo Goto (Japanese Red Cross Gifu Hosp), Hiroshi Fujita (Gifu Univ) MI2014-78 |
The purpose of this study is to develop an automated analysis method to reduce variations in the measurement of mean cer... [more] |
MI2014-78 pp.115-118 |
MI |
2014-09-02 15:40 |
Tokyo |
The Institute of Statistical Mathematics |
Comparison of SUVs and Z-scores on torso FDG-PET/CT scans based on statistical image analysis method Miho Shimizu, Takeshi Hara, Xiangrong Zhou, Chisako Muramatsu (Gifu Univ.), Satoshi Itoh (Daiyukai General Hospital), Shinichiro Kumita, Keiichi Ishihara (Nippon Medical School), Tetsuro Katafuchi (Gifu Univ. of Medical Science), Hiroshi Fujita (Gifu Univ.) MI2014-42 |
The purpose of this study is to develop a statistical analysis method of glucose metabolism on torso FDG-PET/CT scans. T... [more] |
MI2014-42 pp.39-42 |
MI |
2014-01-26 13:30 |
Okinawa |
Bunka Tenbusu Kan |
Analysis and construction of normal model on torso FDG-PET scans based on lean body mass Yusuke Shimizu, Takeshi Hara, Daisuke Fukuoka, Xiangrong Zhou, Chisako Muramatsu (Gifu Univ.), Satoshi Itoh (Daiyukai General Hospital), Kenta Hakozaki, Shinichiro Kumita, Keiichi Ishihara (Nippon Medical School), Tetsuro Katafuchi (GUMS.), Hiroshi Fujita (Gifu Univ.) MI2013-74 |
We have constructed Standardized Uptake Value (SUV) models from the normal FDG-PET scans. The purpose of this study was ... [more] |
MI2013-74 pp.97-101 |
MI |
2013-01-24 11:30 |
Okinawa |
Bunka Tenbusu Kan |
[Special Talk]
Computer-aided diagnosis and measurements for PET and scintigrams Takeshi Hara (Gifu Univ.), Tetsuro Katafuchi (Gifu Univ. of Medical Science), Hiroshi Fujita (Gifu Univ.) MI2012-67 |
[more] |
MI2012-67 pp.31-32 |
MI |
2012-10-29 14:45 |
Yamaguchi |
Yamaguchi Univ. |
Measurements of depth recognition on stereoscopic scintigrams based on two-altanative forced choice task Takeshi Hara, Katsuaki Yamazaki (Gifu Univ.), Tetsuro Katafuchi (Gifu Med. Univ.), Tatsunori Kobayashi (Junshin Univ.), Masaki Matsusako (St. Luke Hosp.), Chisako Muramatsu, Xiangrong Zhou, Hiroshi Fujita (Gifu Univ.) MI2012-58 |
It is difficult for readers to recognize object depth and overlap in a single scintigraphy. The purpose of this work was... [more] |
MI2012-58 pp.55-58 |
MI |
2012-01-19 10:15 |
Okinawa |
|
Evaluation of anatomical registration method for torso FDG-PET scans Yusuke Shimizu, Tokifumi Suzuki, Tatsunori Kobayashi, Takeshi Hara, Xiangrong Zhou (Gifu Univ.), Satoshi Itoh (Daiyukai General Hospital.), Shinichiro Kumita, Keiichi Ishihara (Nippon Medical School), Tetsuro Katafuchi (GUMS.), Hiroshi Fujita (Gifu Univ.) MI2011-78 |
The purpose of this study was to evaluate our automated anatomical registration method for torso FDG-PET scans. Registra... [more] |
MI2011-78 pp.7-10 |
MI |
2012-01-20 11:25 |
Okinawa |
|
Analysis of temporal changes and anatomical Standardized Uptake Value model on torso FDG-PET scans. Tokifumi Suzuki, Yusuke Shimizu, Tatsunori Kobayashi, Takeshi Hara, Xiangrong Zhou (Gifu Univ.), Satoshi Ito (Daiyukai General Hospital), Tetsuro Katafuchi (Gifu University of Medical Science), Hiroshi Fujita (Gifu Univ.) MI2011-128 |
The purpose of this study is to analyze temporal changes and anatomical normal Standardized Uptake Value (SUV) models on... [more] |
MI2011-128 pp.281-285 |
MI |
2010-11-15 15:30 |
Kyoto |
Shimadzu Corp. |
Depth measurement of accumulation position in stereoscopic scintigraphy Tatsunori Kobayashi (Gifu Univ.), Ayaka Wakahara (GUMS.), Takeshi Hara (Gifu Univ.), Tetsuro Katafuchi (GUMS.), Xiangrong Zhou, Hiroshi Fujita (Gifu Univ.) MI2010-78 |
In the scintigraphy inspection, the accumulation position is done to specific of accumulation by using the front image a... [more] |
MI2010-78 pp.67-70 |
MI |
2010-07-09 16:10 |
Tokushima |
Tokusima Univ. Kogyo-Kaikan Bldg. |
Automatic detection and temporal comparison methods for lesions on torso FDG-PET scans Tomoya Asai, Tokifumi Suzuki, Takeshi Hara, Tatsunori Kobayashi, Xiangrong Zhou (Gifu Univ), Satoshi Itoh (Daiyukai General Hospital.), Tetsuro Katafuchi (GUMS), Hiroshi Fujita (Gifu Univ) MI2010-46 |
The purpose of this study is to develop a technique for the computer-aided diagnosis (CAD) system to track lesions by an... [more] |
MI2010-46 pp.51-56 |
PRMU, IE, MI |
2009-05-29 14:45 |
Gifu |
Gifu Univ. |
Automatic estimation of the malignant tumors using normal SUV model in torso FDG-PET images Tomoya Asai, Tokifumi Suzuki, Takeshi Hara, Tatsunori Kobayashi, Xiangrong Zhou (Gifu Univ), Satoshi Ito (Daiyukai General Hospital), Tetsuro Katafuchi (Gifu Univ. of Medical Sci.), Hiroshi Fujita (Gifu Univ) IE2009-46 PRMU2009-37 MI2009-37 |
This study evaluates malignant tumors of the torso FDG-PET images for CAD system. We investigate quantitative estimation... [more] |
IE2009-46 PRMU2009-37 MI2009-37 pp.205-208 |
PRMU, IE, MI |
2009-05-29 15:15 |
Gifu |
Gifu Univ. |
Development of a computer-aided-diagnosis system based on temporal-subtraction tehnique in torso FDG-PET image. Tokifumi Suzuki, Tomoya Asai, Tatsunori Kobayashi, Takeshi Hara, Xiangrong Zhou (Gifu Univ), Satoshi Ito (Daiyukai Hospital), Tetsuro Katafuchi (Gifu Univ of Medical Science), Hiroshi Fujita (Gifu Univ) IE2009-47 PRMU2009-38 MI2009-38 |
The purpose of this study is to develop a technique for the computer-aided diagnosis (CAD) system in torso FDG-PET image... [more] |
IE2009-47 PRMU2009-38 MI2009-38 pp.209-212 |
MI |
2008-07-16 13:30 |
Hokkaido |
Sapporo Medical University |
Automated scoring and temporal subtraction system on FDG-PET images Takeshi Hara, Tatsunori Kobayashi, Xiangrong Zhou (Gifu Univ.), Tomoya Asai, Tokifumi Suzuki (Gifu Univ), Satoshi Ito (Gifu Univ. of Med. Sci.), Tetsuro Katafuchi (Faculty of Health Science), Hiroshi Fujita (Gifu Univ.) MI2008-22 |
[more] |
MI2008-22 pp.15-18 |
MI |
2008-01-26 13:00 |
Okinawa |
Naha-Bunka-Tenbusu |
Quantitative estimation of Standardized Uptake Value (SUV) based on torso normal SUV distribution on Whole body FDG-PET images. Tatsunori Kobayashi, Kazunao Kawai, Takeshi Hara, Xiangrong Zhou (Gifu Univ.), Satoshi Itoh (Daiyukai General Hospital), Tetsuro Katafuchi (GUMS.), Hiroshi Fujita (Gifu Univ.) MI2007-133 |
FDG-PET has semi-quantitative measurements of glucose metabolism using SUV (Standardized Uptake Value) to distinguish be... [more] |
MI2007-133 pp.389-392 |