Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
EMD, EMCJ |
2009-05-22 15:50 |
Tokyo |
Kanda camupus, Nippon Institute of Technology |
Equivalent Circuit Expressions for EMI Problems in PLC Yoshio Kami (Univ. of Electro-Comm.), Akira Sugiura (NICT) EMCJ2009-20 EMD2009-12 |
Power line communication (PLC) is a system using a main-line network without newly constructing any transmission line sy... [more] |
EMCJ2009-20 EMD2009-12 pp.61-66 |
EMCJ |
2009-01-23 10:05 |
Fukuoka |
|
[Special Talk]
EMC Technologies in Switching Converters Tamotsu Ninomiya (Nagasaki University) EMCJ2008-102 |
Abstract Recently a lot of switching converters have been used in almost all electronic equipments, and they have been ... [more] |
EMCJ2008-102 pp.1-6 |
EMCJ |
2009-01-23 13:50 |
Fukuoka |
|
Transmission-line-circuit theory for EMC problems in main-line distribution Yoshio Kami, Fengchao Xiao (Univ. Electro-Commu.), Kimitoshi Murano (Tokai Univ.) EMCJ2008-107 |
Power-line communication (PLC) using an inhouse main-power line needs not to construct a additional new transmission lin... [more] |
EMCJ2008-107 pp.29-34 |
EMCJ |
2008-07-17 13:15 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Estimation of Electromagnetic Emission from PCBs with a Connector through the Common-mode Antenna Model (part2)
-- Model Improvement by Considering Connector Inductance -- Yuri Wakaduki, Makoto Torigoe (Okayama Univ.), Tetsushi Watanabe (ITCO), Yoshitaka Toyota, Kengo Iokibe, Ryuji Koga (Okayama Univ.) EMCJ2008-32 |
In this paper, we apply a connector model with an inductance to the common-mode antenna model. The common-mode antenna m... [more] |
EMCJ2008-32 pp.37-42 |
EMCJ |
2008-03-07 09:35 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment III Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-117 |
The radiated electric field (REF) of the in-house broadband power line communications (PLC) in Japan is supposed to be b... [more] |
EMCJ2007-117 pp.1-6 |
EMCJ |
2008-01-25 15:00 |
Saga |
Saga University |
A study of the placement of common-mode points in the WBFC method for EM-immunity test Naoki Kagawa (Fukuyama Univ.) EMCJ2007-113 |
To find the optimum measurement condition of the immunity test with the workbench faraday cage (WBFC) method, the author... [more] |
EMCJ2007-113 pp.43-48 |
EMCJ, MW |
2007-10-25 09:35 |
Miyagi |
Tohoku University |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment II Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-53 MW2007-100 |
Japanese regulations of in-house broadband power line communications (PLC)
are supposed to suppress the radiated electr... [more] |
EMCJ2007-53 MW2007-100 pp.1-6 |
CAS, NLP |
2007-10-18 14:00 |
Tokyo |
Musashi Institute of Technology |
An Approach for Reducing Common-Mode Current on Electronic Control Units Using Optimization Algorithm Kohei Shinomiya, Hideki Asai (Shizuoka Univ.), Takanori Uno (DENSO) CAS2007-45 NLP2007-73 |
With the progress of packaging technologies, electronic circuits are designed with smaller devices and higher clock spee... [more] |
CAS2007-45 NLP2007-73 pp.61-66 |
EMCJ |
2007-09-21 11:25 |
Kyoto |
Doshisha University |
Balance Control of Power-supply Interconnection in Printed Circuit Boards and ICs for Reduction of Common-mode Current Flowing on Attached Cables Kenta Mizui, Osami Wada, Umberto Paoletti, Takashi Hisakado (Kyoto Univ.) EMCJ2007-45 |
In this report, the balance control of a simple circuit consisting of a PCB with an IC having one power-supply line and ... [more] |
EMCJ2007-45 pp.13-18 |
EMCJ |
2007-09-21 14:25 |
Kyoto |
Doshisha University |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment I Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-49 |
In Japan, in-house broadband power line communications (PLC) are regulated only in terms of the common-mode current (CMI... [more] |
EMCJ2007-49 pp.37-42 |
EMCJ |
2007-06-22 13:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Estimation of Radiated Emissions with Common-mode Antenna Model of Printed Circuit Board
-- Superposition of Common-mode Excitation Sources -- Keisuke Fukumasu (Okayama Univ.), Tetsushi Watanabe (ITCO), Yoshitaka Toyota, Kengo Iokibe, Ryuji Koga (Okayama Univ.), Osami Wada (Kyoto Univ.) EMCJ2007-25 |
A common-mode antenna model proposed by the authors is able to predict common-mode radiation from printed circuit boards... [more] |
EMCJ2007-25 pp.39-44 |
EMCJ |
2007-04-27 16:45 |
Tokyo |
NICT |
Estimation of Electromagnetic-emission from PCBs with a Connector through the Common-mode Antenna Model Akifumi Sadatoshi, Youhei Sakai (Okayama Univ.), Tetsushi Watanabe (ITCO), Yoshitaka Toyota, Kengo Iokibe, Ryuji Koga (Okayama Univ.), Osami Wada (Kyoto Univ.) EMCJ2007-9 |
The amount of radiated emission from the connector between the motherboard and the daughterboard depends on the number o... [more] |
EMCJ2007-9 pp.49-54 |
EMCJ |
2007-03-09 16:15 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Common-mode current related to cable ground in shape Kazuya Morimitsu (Okayama Univ.), Tetsushi Watanabe (ITCO), Yoshitaka Toyota, Ryuji Koga (Okayama Univ.), Osami Wada (Kyoto Univ.) EMCJ2006-128 |
Common-mode current was measured for a four-conductor system that is electrically floating above the reference ground.
... [more] |
EMCJ2006-128 pp.71-75 |
EMCJ |
2006-12-15 13:35 |
Aichi |
Nagoya Institute of Technology |
Technique of Radio Noise Estimation in Vehicle-Mounted Communication Network Youichirou Suzuki, Noboru Maeda (SOKEN), Nobuyuki Iwasaki (DENSO) EMCJ2006-89 |
The EM noise emission in radio band from wire harnesses (radio noise) is evaluated by actual measurement test complying ... [more] |
EMCJ2006-89 pp.47-52 |
EMCJ |
2006-07-27 09:05 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Analysis of Emission from Printed Circuit Board with Linear Conductor Masahiro Takashima, Teruo Tobana, Takayuki Sasamori, Kohshi Abe (Akita Pref. Univ.) EMCJ2006-18 |
Emission from a printed circuit board(PCB) with a finite size
become serious when common mode (dipole mode) currents ar... [more] |
EMCJ2006-18 pp.1-4 |
EMCJ |
2005-12-09 14:10 |
Gifu |
Gifu University |
Estimation of Common-Mode Current in Vehicle-Mounted LAN Kazuhisa Ishimaru, Noboru Maeda (SOKEN), Takashi Murase, Koji Kondo (DENSO) |
Recently emission noise, induced by common-mode current through vehicle-mounted LAN, has been a lot of risk to make surr... [more] |
EMCJ2005-121 pp.41-44 |
EMCJ, MW |
2005-10-28 13:20 |
Akita |
Akita University |
Emission from printed circuit board with ground plate with side plates Teruo Tobana, Takayuki Sasamori, Kohshi Abe (Akita Pref. Univ.) |
In order to suppress the emission from a printed circuit board
with a finite ground plane and a microstrip line,
the... [more] |
EMCJ2005-99 MW2005-105 pp.37-41 |
EMCJ |
2005-09-09 11:45 |
Kyoto |
Kyoto University |
Equivalent Representation of Indoor Power Outlet for Power Line Communication and Common-mode Current Yoshio Kami (Univ. of Electro-Commun.) |
In Japan a power line communication (PLC) system is proposed as the system using indoor power lines in a short-wave band... [more] |
EMCJ2005-71 pp.73-78 |
EMCJ, EMD |
2005-07-28 15:10 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
A Method to Estimate the Radiated Emission Utilizing Common-mode Potential Distribution in a Printed Circuit Board Youhei Sakai, Ryuji Koga (Okayama Univ.), Tetsushi Watanabe (ITCO), Osami Wada (Kyoto Univ.) |
In this report, we propose a method to estimate the common-mode radiation from a printed circuit board (PCB) with a high... [more] |
EMCJ2005-49 EMD2005-28 pp.45-50 |
EMCJ, EMD |
2005-07-29 13:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Examination for imbalance matching at receiver terminal in high speed differential transmission system Kazuya Morimitsu, Hiroshi Shigenari, Yoshitaka Toyota, Ryuji Koga (Okayama Univ.), Osami Wada (Kyoto Univ.) |
In differential signaling,the circuit configuration must be symmetric. If its configuration is asymmetric,common-mode cu... [more] |
EMCJ2005-54 EMD2005-33 pp.7-12 |