Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Basic Study of Monitoring System for Effective Hyperthermia Treatment Keito Nakamura, Yuya Iseki, Yasuhiro Shindo, Kazuo Kato (Meiji Univ.) MI2014-73 |
[more] |
MI2014-73 pp.97-98 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
The effects of age and sex difference of the glucose metabolism in the hippocampus using Positron Emission Tomography Ken Ikeda, Tetsuo Sato, Shigehiko Kanaya (NAIST), Toru Hoshida (Nara Medical Center) MI2014-74 |
For the early detection of temporal lobe epilepsy and prognosis, the hippocampus is targeted in the diagnosis by positro... [more] |
MI2014-74 pp.99-103 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
A method to extract fibrosis area from HE-stained liver specimens using the superpixel Masahiro Ishikawa (Saitama Med Univ.), Ryota Kudo, Hiroshi Kanazawa, Masahiro Yamaguchi (Tokyo Tech), Hideki Komagata, Naoki Kobayashi (Saitama Med Univ.), Yoshiko Yamashita, Tomoharu Kiyuna (NEC), Tokiya Abe, Akinori Hashiguchi, Michiie Sakamoto (Keio Univ) MI2014-75 |
In the diagnosis of hepatocellular carcinoma(HCC) by HE-stained liver pathological specimens, the structure of hepatic c... [more] |
MI2014-75 pp.105-108 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Temperature estimation during hyperthermia treatments with mean blood flow and inside artery and vein Junichi Nagasawa, Syuya Goto, Yuya Iseki, Yasuhiro Shindo, Kazuo Kato (Meiji Univ.) MI2014-76 |
This paper describes heating properties of a resonant cavity applicator for heating brain tumors calculated by a computa... [more] |
MI2014-76 pp.109-110 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Semi-automatic region detection of maxillary sinus on dental panoramic radiograph Yuma Miki, Takeshi Hara, Chisako Muramatsu (Gifu Univ.), Tatsuro Hayashi (Media), Akitoshi Katsumata (Asahi Univ.), Xiangrong Zhou, Hiroshi Fujita (Gifu Univ.) MI2014-77 |
Recently, a diagnosis using a dental panoramic radiograph is frequently performed. We previously developed a method to d... [more] |
MI2014-77 pp.111-114 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Automated analysis of mean cerebral blood flow based on Patlak plot method Tomohiko Kobota, Takeshi Hara (Gifu Univ), Hiroshi Tago (Japanese Red Cross Gifu Hosp), Daisuke Fukuoka (Gifu Univ), Tetsuro Katafuchi (GUMS), Hiroo Goto (Japanese Red Cross Gifu Hosp), Hiroshi Fujita (Gifu Univ) MI2014-78 |
The purpose of this study is to develop an automated analysis method to reduce variations in the measurement of mean cer... [more] |
MI2014-78 pp.115-118 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Image registration for myocardial perfusion MRI to facilitate examing ischemic patients while breathing Akihiro Manabe, Tetsuo Sato (NAIST), Tomohisa Okada (Kyoto Univ.), Shigehide Kuhara (TMSC), Kaori Togashi (Kyoto Univ.), Shigehiko Kanaya (NAIST), Kotaro Minato (ASTEM) MI2014-79 |
Myocardial Perfusion MRI (Magnetic Resonance Imaging) is one of the useful tools to examine ischemic heart disease. For ... [more] |
MI2014-79 pp.119-124 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Improvement of representation for three-dimensional reconstruction and visualization of serial histological specimens Ryo Haraguchi (NCVC), Hirofumi Seo (Sciement), Taka-aki Matsuyama, Yoshiaki Morita, Michiaki Iwata, Shuhei Hasegawa, Hatsue Ishibashi-Ueda (NCVC) MI2014-80 |
[more] |
MI2014-80 pp.125-128 |
MI |
2015-03-02 13:40 |
Okinawa |
Hotel Miyahira |
Improving the user interface of a surgical navigation system using voice-activated control Masahiro Hayashi, Keisuke Doman, Yoshito Mekada (Chukyo Univ.), Kazunari Misawa (Aichi Cancer Center), Kensaku Mori (Nagoya Univ.) MI2014-81 |
We aim at developing a surgical navigation system which can be controlled by an operating surgeon with his/her voice.The... [more] |
MI2014-81 pp.129-132 |
MI |
2015-03-02 15:10 |
Okinawa |
Hotel Miyahira |
[Memorial Lecture]
Development of ultrasound elastography- for medical innovation by integrative research of medicine and engineering- Tsuyoshi Shiina (Kyoto Univ.) MI2014-82 |
[more] |
MI2014-82 pp.133-136 |
MI |
2015-03-02 16:00 |
Okinawa |
Hotel Miyahira |
Segmentation of Blood Vessels in Retinal Fundus Images using Morphology Filter Bank and Artificial Neural Network Tomoki Inoue, Ryutaro Hashimoto, Yoshikazu Uchiyama, Keiichi Uchimura, Gou Koutaki (Kumamoto Univ.) MI2014-83 |
We propose a method for segmentation of blood vessels in retinal fundus images. In this method, we use a morphology filt... [more] |
MI2014-83 pp.137-141 |
MI |
2015-03-02 16:12 |
Okinawa |
Hotel Miyahira |
Imaging position recognition of CT images using deep learning for computational medical image understanding. Fumiyasu Noshiro, Masahito Aoyama, Yoshitaka Masutani (Hiroshima City Univ.) MI2014-84 |
In this paper, we describe our method based on deep learning and majority voting for imaging position recognition, which... [more] |
MI2014-84 pp.143-146 |
MI |
2015-03-02 16:24 |
Okinawa |
Hotel Miyahira |
Segmentation of Organ Regions in Medical Images using Hierarchical Active Shape Models Shohei Kamiya, Hidekata Hontani (NIT) MI2014-85 |
In this article, the authors report on a hierarchical parametric Active Shape Model (ASM). Different from conventional A... [more] |
MI2014-85 pp.147-150 |
MI |
2015-03-02 16:36 |
Okinawa |
Hotel Miyahira |
Eliminations of dura maters from MR Images using probablistic atlas and graph cut technique Shin-ya Uto, Hidekata Hontani (NIT), Muneyuki Sakata (TMIG), Yuichi Kimura (Kinki Univ) MI2014-86 |
This study aims at proposing algorithm that liminate the dura maters in brain MR images accurately. Ordinary methods oft... [more] |
MI2014-86 pp.151-155 |
MI |
2015-03-02 16:48 |
Okinawa |
Hotel Miyahira |
Decision of Pulmonary Areas of Thoracic CT Images by use of Anatomical Structures and Pulmonary Textures Kyohei Karasawa, Yasushi Hirano, Shoji Kido (Yamaguchi Univ.), Kazuki Kozuka (Panasonic) MI2014-87 |
In order to analyze diffuse lung diseases in the thoracic CT images by computer-aided diagnosis (CAD) systems, it is nec... [more] |
MI2014-87 pp.157-160 |
MI |
2015-03-03 09:00 |
Okinawa |
Hotel Miyahira |
Improvement of Detection Limit in Fluorescent X-ray Computed Tomography due to Multi-Pinhole Effect Tenta Sasaya (Yamagata Univ), Naoki Sunaguchi (Gunma Univ), Dai Aoki, Tetsuya Yuasa (Yamagata Univ), Kazuyuki Hyodo (KEK), Tsutomu Zeniya (NCVC) MI2014-88 |
So far, we have developed a fluorescent x-ray computed tomography using a pinhole effect. However, since S/N of projecti... [more] |
MI2014-88 pp.161-166 |
MI |
2015-03-03 09:12 |
Okinawa |
Hotel Miyahira |
Non-invasive quality evaluation of confluent cells by orientation analysis Kei Sasaki (Yamagata Univ.), Hiroto Sasaki, Atsuki Takahashi, Kei Kanie (Nagoya Univ.), Siu Kang (Yamagata Univ.), Ryuji Kato (Nagoya Univ.), Tetsuya Yuasa (Yamagata Univ.) MI2014-89 |
Although regenerative medicine is rapidly evolving toward clinical application in recent years, the fact that no effecti... [more] |
MI2014-89 pp.167-172 |
MI |
2015-03-03 09:24 |
Okinawa |
Hotel Miyahira |
Generating 4D-CT image using motion information obtained from 4D-MR image Shuhei Isa, Takashi Ohnishi (Chiba Univ), Yoshitada Masuda, Ken Motoori, Takashi Uno (Chiba University Hospital), Hideaki Haneishi (Chiba Univ) MI2014-90 |
In the highly accurate radiation therapies of thoracic region, the tumor and organ motion greatly impacts on the result ... [more] |
MI2014-90 pp.173-176 |
MI |
2015-03-03 09:36 |
Okinawa |
Hotel Miyahira |
Generation of CT images at arbitrary time phase using chest 4D-CT images Michiaki Nakagawa, Yasushi Hirano, Shoji Kido (Yamaguchi Univ.) MI2014-91 |
Recently,development of Computer-Aided Diagnosis(CAD)technology is remarkable. CAD technologies for respiratory system a... [more] |
MI2014-91 pp.177-182 |
MI |
2015-03-03 09:48 |
Okinawa |
Hotel Miyahira |
Quality Improvement of SPECT Images via Random Coded Aperture and Compressed Sensing Takenori Segawa, Toshiyuki Tanaka (Kyoto Univ.) MI2014-92 |
There is a trade-off between quality of reconstructed images and
discomfort of patients, caused by long scan time and... [more] |
MI2014-92 pp.183-188 |